Section Iii. Replacing A Lamp Only - Pentair Water SunBrite II Manual Del Propietario - Operador

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2. To remove light assembly, remove the special pilot screw at top of face ring, remove light assembly from niche,
and place assembly on deck.
Be sure to keep the special pilot screw from this underwater light. This screw mounts and electrically grounds the housing securely
to the mounting ring and wet niche. Failure to use the screw provided could create an electrical hazard which could result in death
or serious injury to pool users, installers or others due to electrical shock.
3. Remove Junction Box cover, disconnect the light fixture wires, and pull the cord through the conduit.
4. Feed the new light fixture cord through the conduit from the niche to the Junction Box.
Depending on the length of the conduit, special tools may be required to pull the cord through the conduit.
5. Leave at least 4 feet of cord to coil around the light fixture; see Figure 1. This 4 feet of cord coiled around the light
allows the light to be serviced after the pool is filled with water.
6. Cut the cord at the Junction Box, leaving at least 6 inches of cord to make connections.
7. Strip 6 inches of the outer cord jacket from the cord to expose the three insulated wires – be careful not to damage
the insulation on the three inner wires.
8. Connect all three wires to the corresponding circuit wires in the Junction Box (black wire to power, white wire to
common, and green wire to ground) and secure the Junction Box cover in place.
Never operate this underwater light for more than 10 seconds unless it is totally submerged in water. Without total submersion, the
light assembly will get extremely hot, which may result in serious burns or in breakage of the lamp or lens. This may result in serious
injury to pool users, installers, or bystanders, or in damage to property.
9. Replace light assembly into the niche and tighten the special pilot screw.
Use only the special pilot screw provided with this underwater light. This screw mounts and electrically grounds the housing securely
to the mounting ring and wet niche. Failure to use the screw provided could create an electrical hazard which could result in death
or serious injury to pool users, installers or others due to electrical shock.
10. Fill the pool until the underwater light is completely submerged in water before operating the light for more than
10 seconds. Turn on main switch or circuit breaker, as well as the switch which operates the underwater light
itself, to check for proper operation.

Section III. Replacing a lamp only

Always disconnect power to the pool light at the circuit breaker before servicing the light. Failure to do so could result in death
or serious injury to installer, serviceman, pool users or others due to electrical shock.
1. Turn off main electrical switch or circuit breaker, as well as the switch which operates the underwater light itself.
2. You will need to get the following items.
a. A new lens gasket, p/n 79101601.
b. A lamp, see Table 1 for proper wattage
and type.
Rev C • Rev C • Rév C 10-29-07
WARNING
NOTE
WARNING
WARNING
DANGER
Table 1, Lamp Specifications.
Voltage
Wattage
120
300
12
50
12
100
5
No. Req.
Lamp type
1
T-3 R7S
2
T-3 GY 6.35
2
T-3 GY 6.35
P/N • Núm/Pte. • Réf. 619692
P/N
79131000
79131400
79131200

Publicidad