Troubleshooting - MIRKA 912 Instrucciones De Manejo

Ocultar thumbs Ver también para 912:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 56
GB
Mirka 912/915
D

Troubleshooting

F
Fault
NL
Motor does not start
I
N
S
DK
FIN
E
Motor does not run
in automatic mode
P
GR
TR
Reduced suction
power
SLO
CZ
PL
RUS
EST
LV
LT
CN
JP
No suction power
during wet cleaning
Voltage fluctuations
4
Cause
>
Fuse of the mains socket
has blown.
>
Overload protection switch
has tripped.
>
Motor is faulty.
>
Power tool/pneumatic tool is
defective or not connected
properly.
>
The power rating of the
electrical tool is too low.
>
Suction power selected with
suction power control is too
low.
>
Clogged suction hose/noz-
zle.
>
Tank or Fleece bag is full.
>
Filter element is clogged.
>
Seal between tank and
upper section of vacuum
cleaner is faulty or missing.
>
Cleaning mechanism is
defective.
>
Tank is full.
>
Impedance of power supply
is too high.
Remedy
Connect mains fuse.
Switch off the vacuum
cleaner and allow it to cool
for approx. 5 minutes. If the
cleaner cannot be started
again, contact the Mirka
Service department.
Have motor changed by
Mirka Service.
Check that the power tool
works or that the plug is
inserted correctly.
Note that minimum power
rating is P>40W
Set suction power in ac-
cordance with section „Set-
ting suction power".
Clean suction hose/nozzle
See „Emptying tank" or
„Replacing Fleece bag"
sections.
See section „Cleaning filter
element" and „Replacing
filter element".
Replace seal.
Contact Mirka Service.
Switch off the cleaner.
Empty the tank.
Connect the cleaner to
another socket closer to the
fuse box. Voltage fluctua-
tions over 7% should not
occur if the impedance
at the transfer point is
≤ 0.15 Ω .

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

915