Beretta Ciao Green 25 C.S.I. Manual De Instalacion Y Uso página 8

Ocultar thumbs Ver también para Ciao Green 25 C.S.I.:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
CIAO GREEN C.S.I.
Ciao Green 25 C.S.I.
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
0
5
10
15
20
25
30
35
40
Suction pipe length (m)
Twin pipes ø 80 with ducting Ø50 - Ø60 - Ø80 (fig. 24)
Thanks to the boiler characteristics, a flue gas discharge pipe ø 80 can
be connected to the ducting ranges Ø50 - Ø60 - Ø80.
b
For the ducting, you are advised to make a project calculation in order
to respect the relevant standards in force.
The table shows the standard configurations allowed.
Table of standard pipe configurations (*)
1 bend 90° ø 80
Air suction
4,5m pipe ø 80
1 bend 90° ø 80
4,5m pipe ø 80
Flue gas discharge
Reduction from ø 80 to ø50, from ø 80 to ø 60
stack base bend 90°, ø 50 or ø 60 or ø 80
For ducting pipe lengths see table
(*) Use flue gas system accessories in plastic (PP) for condensing boilers:
Ø50 and Ø80 H1 class and Ø60 P1 class.
The boilers are factory set to:
25 C.S.I.: 4.900 r.p.m. (CH) and 6.100 r.p.m. (DHW) and the maximum
length that can be reached is 7m for the ø 50 pipe, 25m for the ø 60 pipe
and 75m for the ø 80 pipe.
29 C.S.I.: 5.300 r.p.m. (CH) and 6.200 r.p.m. (DHW) and the maximum
length that can be reached is 5m for the ø60 pipe and 67m for the ø 80 pipe
(not applicable for the ø 50 pipe).
Should it be necessary to achieve greater lengths, compensate the pressure
drop with an increase in the r.p.m.of the fan, as shown in the adjustments
table, to ensure the rated heat input.
b
The minimum calibration is not modified.
Adjustments table
Maximum number
of fan rotations
r.p.m.
CH
DHW
4.900
6.100
25 C.S.I.
5.000
6.200
5.100
6.300
5.300
6.200
29 C.S.I.
5.400
6.300
Maximum number
of fan rotations
r.p.m.
CH
DHW
4.900
6.100
25 C.S.I.
5.000
6.200
5.100
6.300
5.300
6.200
29 C.S.I.
5.400
6.300
8
MAXIMUM STRAIGHT LENGTH Ø 80
45
50
55
60
65
70
75
80
85
90
Ducting pipes Ø 50 (*)
maximum length (m)
7
9
12 (**)
not applicable
2
Ducting pipes Ø 60 (*)
maximum length (m)
25
30
38 (**)
5
13
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
100
110
95
105
0
5
10
15
Maximum number
25 C.S.I.
29 C.S.I.
(*)
Use fumes exhaust plastic systems (PP) for condensing boilers.
(**) Maximum installable length ONLY with exhaust pipes in H1 class.
Configurations Ø50 or Ø60 or Ø80 show test data verified in the laboratory.
In the case of installations that differ from those indicated in the "standard
configuration" and "adjustments" tables, refer to the equivalent linear
lengths below.
b
In any case, the maximum lengths declared in the booklet are
guaranteed, and it is essential not to exceed them.
COMPONENT Ø 50
Bend 45° Ø 50
Bend 90° Ø 50
Extension 0.5m Ø 50
Extension 1.0m Ø 50
Extension 2.0m Ø 50
COMPONENT Ø 60
Bend 45° Ø 60
Bend 90° Ø 60
Extension 0.5m Ø 60
Extension 1.0m Ø 60
Extension 2.0m Ø 60
Ciao Green 29 C.S.I.
20
25
30
35
40
45
50
55
60
Suction pipe length (m)
Ducting pipes Ø 80 (*)
of fan rotations
maximum length (m)
r.p.m.
CH
DHW
4.900
6.100
5.000
6.200
5.100
6.300
5.300
6.200
5.400
6.300
Linear equivalent in metres Ø80 (m)
Linear equivalent in metres Ø80 (m)
65
70
75
80
85
90
95
75
90
113 (**)
67
182
12,3
19,6
6,1
13,5
29,5
5
8
2,5
5,5
12

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ciao green 29 c.s.i.

Tabla de contenido