Lega Eco Vario Manual De Instrucciones página 21

Extractor de miel
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

The right or left rotation is also indicated by the led found beside the 'manual' writing: rit will turn red
for negative values and green for positive values.
6 Press the Start/Stop button to stop rotation and allow the half lid to be opened.
3.8 'Automatic' and 'Reverse' operation modes
1 Release the emergency button and turn it clockwise by half turn. The display units, the settings leds
and the previously selected program led will all light up.
2 Press the time/program selector.
3 Turn the time/program selector to the Automatic or teh Reverse mode position. Press to confirm.
4 Press the Start/Stop button.
5 Turn the speed selector to set cage rotation speed.
Rotate the selector clockwise to set positive values and hence cage right rotation; rotate counter-
clockwise to set the cage rotate in the opposite direction.
In the Reverse mode, only the initial rotation is set followed by right and left alternate rotations
according to the program selected.
The right or left rotation is also indicated by the led found beside the 'manual' writing: rit will turn red
for negative values and green for positive values.
6 Rotate the time selector to set the cycle total time, expressed in minutes.
7 Press the Start/Stop button to star the cycle.
8 The leds will signal the RUN status.
The TIME display will indicate the time, expressed in minutes, left to cycle end.
The SPEED display will indicate the actual cage rotation speed expressed in rpm.
9 The preset maximum speed and time values can be viewed also during cage rotation by pressing once
the relevant buttons.
10 Press the Start/Stop button to stop the cycle.
ATTENTION! If the machine starts working in a too sudden way, or if it reaches excessively high speeds
with half-full frames, stability problems and frame breaks can be experienced. In case of severe extractor
instability, immediately stop the machine by hitting the red emergency stop button.
For reasons of safety and stability, the maximum rotation speed that can be set is 400 rpm for manual and
automatic programs and 300 rpm for the reverse program.
In addition to this, it is not possible to set a rotation speed lower 100 rpm in the automatic and reverse
programs.
Costruzioni Apistiche – via Maestri del Lavoro 23 – 48018 Faenza
www.legaitaly.com - Tel 054626834 – Fax 054628279 – P.iva 00043230390
21 / 75

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

521052205240526052755300

Tabla de contenido