PRE-INSTALLATION

PRÉ-INSTALLATION - PREINSTALACIÓN
SAFETY NOTICES: please read before installing and using the device
EN
- The Manufacturer declines all liability if the product is installed in rooms with systems or structures
which do not meet the required legal standards or for work carried out by untrained or unqualified
personnel.
CAUTION: FOR INDOOR USE ONLY
CAUTION: TEST THE GROUND FAULT CIRCUIT INTERRUPTER BEFORE EACH USE and ATTENTION:
CAUTION: READ THE INSTRUCTION MANUAL and ATTENTION:
WARNING: DISCONNECT THE ELECTRIC POWER BEFORE SERVICING
MINIMUM SUPPLY CONDUCTOR AMPACITY:
Model 30 ->13AWG
CAUTION: CONNECT ONLY TO A CIRCUIT PROTECTED BY A CLASS A GROUND FAULT CIRCUIT
CAUTION: READ THE INSTRUCTION MANUAL and the connection scheme on pages 9-10
The unused connectors shall be plainly marked BONDING LUGS
USE COPPER CONDUCTORS ONLY
- The device must be installed by qualified technicians only, in line with international standard IEC 60364-1
and US/CANADA electrical code and local regulation.
- The installer must not tamper with the electrical or operating parts of the product and instead should only con-
nect and install the components as indicated in this manual.
- The device must be permanently connected to the mains using a residual-current device (RCD) with nominal
residual current of no more than 30 mA.
- It is mandatory to install a device which allows complete disconnection in overvoltage category III conditions.
This device should be installed on the power supply line, upstream from the device.
Example: main switch (d>1/8") + differential + fuse.
- The electrical connections, the main switch with a differential and fuse, and the control switch must be installed in
compliance with international standard IEC 60364-1 and US/CANADA electrical code and local regulation.
- The shower head must be connected to the equipotential node in the system, where provided for by international
standard IEC 60364-1 and US/CANADA electrical code and local regulation. Use yellow/green cable, which should be
fixed in the terminal provided and labelled.
- Connection to the water mains must be made using new hoses and piping; do not use old hoses and piping.
- This manual constitutes an integral part of the product. Please store it safely in an accessible place.
- The device should not be used by children or people with physical, sensory or mental difficulties or where lacking
knowledge and experience, unless supervised or instructed on how to use the equipment by someone who is re-
sponsible for their safety. Children should be supervised to ensure that they do not play with the product.
- WARNING: The device can be used by children aged 8 years and above, by people with physical, sensory or
mental difficulties, or by those lacking experience and knowledge, provided that they are supervised or have
been informed as to how to use the device safely and understand the inherent risks. Children must not play
with the device. User cleaning and maintenance must not be carried out by unsupervised children.
3