3
CHARACTERISTICS
3. 1
ELECTRONIC BOARD
The electronic boards are manufactured in
compliance with the EEC 73/23 low-voltage
directives. They are supplied with 230V and,
through a built-in transformer, send a volta-
ge of 24V to the following components: gas
valve, safety stat, C.H. and D.H.W. sensor,
external temperature sensor (optional),
modulator, micro divertor valve, flow switch
safety valve, water pressure transducer,
exhaust gas pressure switch, timer-thermo-
stat or "Logica Remote Control".
An automatic and continuous modulation
system enables the boiler to adjust the heat
output to the various system requirements
or the User's needs. The electronic compo-
nents are guaranteed against a temperatu-
re range of 0 to +60°C.
3. 1 . 1
Fault finding
The indicator leds signalling irregular
and/or incorrect operation of the equip-
ment are indicated in fig. 16.
3. 1 .2
Devices
The electronic board is equipped with the
Flashing red led, fan fault towards "BF".
30 minutes after the fan has switched off,
the board will attempt a restart
Red led on, ignition blocked:
rotate selector
CR/OFF/EST/INV/RESET
to release position (
)
to restore operation
Green led off if
power is cut-off
Flashing red led,
safety stat tripped. Rotate
selector CR/OFF/EST/INV/RESET
to release position (
to restore operation
following devices:
– "POT. RISC." trimmer (10 fig. 17)
Sets the maximum heating power value.
To increase the value turn the trimmer
clockwise; to reduce the value turn the
trimmer anticlockwise.
– "POT. ACC." trimmer (6 fig. 17)
Trimmer to vary the pressure level upon
ignition (STEP), of the gas valve.
According to the type of gas for which
the boiler is equipped, the trimmer must
be regulated so as to obtain a pressure
of approx. 3 mbar at the burner for
methane gas and 7 mbar for butane gas
(G30) and propane gas (G31).
To increase pressure, turn the trimmer
clockwise; to reduce pressure, turn the
trimmer counterclockwise.
The slow ignition pressure level can be
set during the first 3 seconds following
burner ignition.
After setting the pressure level upon
ignition (STEP) according to the type of
gas, check that the pressure for hea-
ting is still at the value previously set.
– "MET-GPL" connector (7 fig. 17)
With the connector switched-off, the boiler
is set-up for natural gas; with the connector
communication fault
with "Logica Remote
)
(*) When all 0.5 to 2.5 bar leds are off, check the water pressure
transducer connection.
Flashing red led,
Control"
Flashing red led, flame detection circuit fault
Flashing red led, modulator coil interrupted
Flashing red led, heating sensor fault (SM)
A flashing red Led indicates an anomaly on the D.H.W. sensor
Flashing red led, smoke pressure switch failure
switched-on, the boiler is ready for LPG.
– "ANN. RIT." connector (5 fig. 17):
In the heating phase, the electronic
board is programmed to include a bur-
ner technical delay interval of approx.
90 seconds, which occurs both at
system cold starting and at subsequent
re-ignitions. The aim is to overcome the
problem of repeated ignitions and tur-
ning off with very short time intervals
between. This could occur in particular in
systems presenting high head losses.
At each restart after the period of slow
ignition, the boiler will set itself for about
1 minute at the minimum modulation
pressure, and will then move to the hea-
ting pressure value set.
When the connecting link is inserted,
both the programmed technical pause
and the period of operation at minimum
pressure in the startup phase will be
cancelled. In this case, the times ela-
psing between turning off and subse-
quent re-ignition will depend on a tempe-
rature difference of 5°C detected by the
SM sensor (heating flow sensor).
– Connector Modureg Sel. (14 fig. 17)
With the bridge disconnected the boiler
is predisposed to function with the SIT
Flashing red led, water
pressure is too low (*)
Flashing red led,
plant safety
valve tripped (*)
Fig. 16
95