REPLACEMENT OF THE OSMOTIC MEMBRANE

The service life of an osmotic membrane is normally over 2 years (depending on the quality of the city
water in your area) but the use in unsuitable conditions can drastically reduce this.
In order to replace the membrane, first unplug the power supply and close the water inlet and the storage
tank valve. Proceed as shown in the images below.
1
Unlock the coupling ring and remove the
tubing.
3
Extract the membrane with the help of
pliers.
After membrane replacement, the system needs to be primed! Refer to chapter "Priming" for further
instructions.
16
2
4
Figure 6 – Membrane replacement
Unscrew the cap counter-clockwise.
Insert the new membrane completely, making
sure that the gasket is positioned correctly. Re-
tighten the cap and connect the tubing.
Gasket
Osmo