x2
***
0---
10--
ALT
follow the user guide
Add. 1ch
Add. 2ch
Add. 3ch
Add. 4ch
erase 64
erase 1
language
autoset
Control unit
software version
stat
vers
OK
No total
- +
manoeuvres(in hundreds)
OK
n. cycles
- +
No radio control
devices memorised
n. remotes
OK
- +
List of last 30 errors
err
OK
0---
password
22 - LEO B CBB DL2 3 230 L02-LEO B CBB DL2 3 120 F02-LEO B CBB DL2 3 120 F02 PHOT USA16 - LEO B CBB DL2 3 230 SV
ACCESS MENUS Fig. 1
INSTALLATION MANUAL
150-
1520
See PARAMETERS MENU
See LOGIC MENU
hidden butt
release
desired button
hidden butt
release
desired button
hidden butt
release
desired button
hidden butt
release
desired button
ok
If cancelled
If not present
( 0001 )
KO
If clone, it is disabled
dis
Diagnostics
code
START E external start input activated
STRE
START I internal start input activated
STRI
OPEN input activated
OPEN
CLOSE input activated
CLS
PED pedestrian input activated
PED
TIMER input activated
TIME
STOP input activated
STOP
Activation of PHOT photocell input or, if configured as verified
PHOT
photocell, Activation of the associated FAULT input
Activation of PHOT OP opening photocell input or, if configured
as active verified photocell only when opening, Activation of
PHOP
the associated FAULT input
Activation of PHOT CL closing photocell input or, if configured
as active verified photocell only when closing, Activation of the
PHCL
associated FAULT input
Activation of BAR safety edge input or, if configured as verified
BAR
safety edge, Activation of the associated FAULT input
Activation of BAR safety edge input on slave motor (opposing
door connection) or, if configured as verified safety edge,
BAR 2
Activation of the associated FAULT input
Activation of BAR safety edge input with ACTIVE reversal ONLY
WHILE OPENING, or, if configured as verified safety edge active
baro
only while opening, Activation of the associated FAULT input
Activation of BAR safety edge input with ACTIVE reversal ONLY
WHILE CLOSING, or, if configured as verified safety edge active
barc
only while closing, Activation of the associated FAULT input
SWC motor closing limit switch input activated
SWC
SWO motor opening limit switch input activated
SWO
The board is standing by to perform a complete opening-
closing cycle uninterrupted by intermediate stops in
SET
order to acquire the torque required for movement.
WARNING! Obstacle detection not active
Activation of mechanical release of the motor.
RLS
The following manoeuvre will be performed at low speed.
Photocell test failed
ER01
Safety edge test failed
ER02
Opening photocell test failed
ER03
Closing photocell test failed
ER04
Safety edge test on slave motor failed (opposite leaves
ER05
connection)
8k2 safety edge test failed
er06
Opening safety edge test failed
ER07
bft . . .
Closing safety edge test failed
ER08
+/-
Board hardware test error
Er10, Er11
0000
Er35, Er36
Reverse due to obstacle - Amperostop
Er37, Er38
+/-
Communication error with remote devices
ER50
00
ER70, ER71
Internal system supervision control error.
+/-
ER74, ER75
Consistency error of the control unit's parameters (Logics
ER72
and Parameters)
01.33
02.01
D-track parameter error
ER73
........
Limit switch error
ERf0
Limit switch error always active after operation start
erf1
30.15
Error in setting the SAFE inputs
+/-
ERf3
150-
10--
*** Password entry.
Request with Protection Level
ok
logic set to 1, 2, 3, 4
See RADIO MENU
DESCRIPTION
1520
Scroll up
Scroll down
Con rm/Switch on display
Exit Menù
only with Encoder= 2
35. 4 0
Obstacle threshold
Instantaneous force motor
NOTES
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or parameter/logic setting
Check photocell connection and/or parameter/logic setting
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
-Check connections to motor
-Hardware problems with board (contact technical assistance)
Check for obstacles in path
Ensure that there is no slip in the mechanical clutch
Check connection with serial-connected accessory devices and/or
expansion boards
Try switching the board off and back on again. If the problem persists,
contact the technical assistance department.
Pressing OK the detected settings are confirmed. The board will keep
on working with the detected settings.
The board settings must be checked (Parameters and Logics)
Pressing OK, the board will keep on working with D-track as a default.
An autoset is required
check limit switch connections
Check limit switch and motor connections
Check the setting of the SAFE inputs is correct
prg