For the following please refer to "Overview
of Parts".
CAUTION: Always hold the breast milk
container (8) upright when it contains milk
or the milk may spill out.
1. Unplug the voltage adapter (14) from
the pump unit (13).
2. Unscrew the shield connector (4) and
tubing (9) from the back of the breast
shield (2).
3. Unscrew the breast milk container (8)
from the connection ring (5).
Hygiene is of priority when handling
breast milk and all parts that come
into contact with it. The pump should
therefore only be used in a clean and
sanitized condition. All accessories and
parts that come into contact with breast
milk – silicone breast cushion (1), breast
shield (2), connection ring (5), backflow
valve (6), membrane (7), and breast
milk container (8) – must be thoroughly
cleaned prior to use. Insufficient cleaning
of the pump and/or components can lead
to contamination. Follow the instructions
to ensure proper cleaning.
NOTE: Prior to first use, sanitize the breast
milk container (8) and nipple (15) by boiling
in water for 5 minutes. Use caution when
removing components from hot water.
CAUTION: Unplug the voltage adapter (14)
from the power outlet before cleaning.
1. Disassemble the pump according to
Section 5.
03_62772_5112_A_DEBP_Booklet_REL_2-19-13_Added pages divisible by 4.indd 7
5. Disassembly of the Pump
4. Unscrew the connection ring (5) from
5. Remove the backflow valve (6) from the
6. Carefully remove the membrane (7) from
7. Remove the tubing (9) from the shield
6. Cleaning
2. After each use, wash the following parts
NOTE: The following parts should be
cleaned as needed: pump unit (13), silicone
gasket (3), shield connector (4), silicone
tubing (9), tubing connector (10), connector
(12), and connector cap (11). If the silicone
gasket (3), shield connector (4), tubing
connector (10), connector (12) or connector
cap (11) come into contact with breast milk
or need cleaning, carefully wash these
7
the breast shield (2).
breast shield (2).
the backflow valve (6) by pulling outwards.
connector (4) and tubing connector
(10). Inspect tubing for condensation
or breast milk. If either appears, refer
to "Section 6.1 Cleaning the Tubing" to
immediately clean the tubing.
by hand: silicone cushion (1), breast shield
(2), connection ring (5), backflow valve (6),
membrane (7), and breast milk container
(8). Wash parts using plenty of warm
water and liquid dishwashing soap, then
rinse with hot water for 10 to 15 seconds.
Clean the membrane (7) carefully to avoid
damaging the material. Allow all parts
to dry completely before next use. The
breast milk container (8), collar (16), nipple
(15) and seal disk (17) can also be cleaned
by boiling or in the dishwasher (top-rack).