CAUTION: It is essential to confirm the power output with the use of a clamp meter
LIMITATION OF OUTPUT ON MODELS MATTIRA SYSTEM MAS18
Maximum
MAXIMUM
output
CURRENT
limited to:
L1
18kW
26.0A
15kW
26.0A
12kW
26.0A
9kW
13.0A
6kW
13.0A
3kW
13.0A
CONNECTION THREE-PHASE 3x400V~+N
LIMITATION OF OUTPUT ON MODELS MATTIRA SYSTEM MAS15
Maximum
MAXIMUM
output
CURRENT
limited to:
L1
15kW
21.7A
13kW
21.7A
12kW
8.7A
11kW
21.7A
10kW
13.0A
9kW
13.0A
8kW
13.0A
7kW
8.7A
6kW
8.7A
5kW
8.7A
4kW
-
3kW
13.0A
2kW
-
CONNECTION THREE-PHASE 3x400V~+N
* The standard configuration of the boiler only allows a maximum of 12kW when connected SINGLE-PHASE 230V~.
5.3 HEATING SYSTEM FLUSHING
CAUTION: Flush the heating installation thoroughly prior to installation.
The heating system should be flushed which will remove any debris or contaminants detrimental to the operation and life of
the boiler. Any cleanser or additives used should comply with current standards and the manufacturer's instructions carefully
followed.
NOTE: IT IS IMPORTANT NOT TO USE THE BOILER PRESSURE RELIEF VALVE TO DRAIN OR FLUSH THE SYSTEM AS
TRAPPED DEBRIS WILL CAUSE INCORRECT OPERATION. A PURPOSE PROVIDED DRAIN POINT SHOULD BE USED.
MAXIMUM
MAXIMUM
CURRENT
CURRENT
L2
L3
26.0A
26.0A
26.0A
13.0A
13.0A
13.0A
13.0A
13.0A
13.0A
-
-
-
MAXIMUM
MAXIMUM
CURRENT
CURRENT
L2
L3
21.7A
21.7A
21.7A
13.0A
21.7A
21.7A
13.0A
13.0A
8.7A
21.7A
13.0A
13.0A
8.7A
13.0A
13.0A
8.7A
8.7A
8.7A
13.0A
-
8.7A
8.7A
-
-
-
8.7A
Maximum
output
limited to:
18kW*
15kW*
12kW
9kW
6kW
3kW
CONNECTION SINGLE PHASE 230V~
Maximum
output
limited to:
15kW*
13kW*
12kW
11kW
10kW
9kW
8kW
7kW
6kW
5kW
4kW
3kW
2kW
CONNECTION SINGLE PHASE 230V~
31
MAXIMUM
CURRENT
78.3A*
65.2A*
52.2A
39.1A
26.1A
13.0A
MAXIMUM
CURRENT
65.2A*
56.5A*
52.2A
47.8A
43.5A
39.1A
34.8A
30.4A
26.1A
21.7A
17.4A
13.0A
8.7A