Feeding Expressed Milk With Nuk ® Breast Milk Container; Troubleshooting - NUK Expressive Instrucciones De Operación

Extractor de leche eléctrico individual
Ocultar thumbs Ver también para Expressive:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

9.3 Feeding Expressed Milk with NUK
Milk Container
IMPORTANT SAFEGUARDS FOR THE BREAST
MILK CONTAINER & NIPPLE
WARNING: For safety and health reasons please note
the following:
• Prolonged periods of time drinking liquids, other than
water, may cause tooth decay.
• To prevent possible choking hazard, test strength
before each use by pulling the nipple in all directions.
Any tear can lead to the separation of pieces.
Discontinue use if any tear or crack appears. Do not
attempt to enlarge the hole as this may lead to tearing.
CAUTION:
• Do not overheat. Always test temperature of liquid on
wrist before feeding baby.
• Do not microwave, since this can cause uneven
heating.
• Always supervise baby when feeding.To avoid injury, do
not allow a child to walk or run with a bottle.
Problem
Reason
There is no power
Lip valve (4) is missing or is not
properly attached
Pump does
not work
Pump is being held at too great
an angle
Connection ring is not tight enough
There is no vacuum
Low battery power
Suction strength is set too low
Pump has
only little
suction
Lip valve (4) has a tear
Missing overflow protection valve (1)
Pump
suction too
Suction strength is set too high
powerful
03_62766_5369_A_SEBP_IB_New Pump_REL_8-29-13.indd 11
Breast
CARE:
®
• Disassemble before cleaning. Prior to first use, sanitize
• For day to day cleaning, wash with hot water and mild
• To heat, use a NUK
• For hygiene and safety, replace with appropriate NUK
1. Apply the supplied nipple (13) onto the breast milk
2. The NUK

10. Troubleshooting

Solution
For battery operation check that the
batteries are correctly inserted.
For voltage adapter (7) operation check that the plug is correctly
inserted or try using a different power outlet.
Check that lip valve (4) is attached correctly.
Hold the pump upright. If the pump is held at too great an angle it will
switch off automatically.
Tighten the connection ring.
Ensure that the breast shield is sealed against the breast so no air
escapes.
Replace batteries.
Turn the knob (9) clockwise until the suction strength meets your needs.
Check the lip wall for tears. Replace it with spare lip valve (4), if
damaged.
Disassemble pump and place overflow protection valve (1) in proper
location.
Turn the knob (9) counterclockwise until the suction strength meets
your needs.
11
by boiling in water for 5 minutes.
detergent then rinse clean. Dishwasher-safe (top rack).
Allow to dry before storage.
Bottle Warmer or place the bottle
®
under hot running water or in a container of heated
water.
Nipples after about 2 months of use.
container (5) with the supplied container collar (12). The
NUK
Breast Milk Container can be used with all NUK
®
Wide-Neck Nipples.
Air System vents the bottle, preventing
®
vacuum buildup and allows baby to drink continuously,
swallowing liquid instead of air. Make sure the NUK
Air System symbol on the nipple (13) is lined up under
baby's nose for the best results.
NUK Graphics
SKU
SAP Packaging Number
07_NCI
Engineering Graphic Design
728 Booster Blvd
UPC Code
Die
Product Description
Reedsburg, WI 53959
608-524-9312
N/A
N/A
NUK Logo - Process Black
8/29/2013 12:06:17 PM
®
®
Flat S
N/A
Date
Created
®
1-29-10-pab x
®
®

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido