Theoretical Resistance Chart; Step-By-Step Installation Procedures - LATICRETE Floor HEAT Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

120 VOlT ThEORETiCAl RESiSTAnCE ChART
lATiCRETE
Floor hEAT 120V 15W SQFT
®
Product
SQFT
Power (W)
1' x 10'
10
150
1' x 12'
12
180
1' x 15'
15
225
1' x 20'
20
300
1' x 23'
23
345
1' x 25'
25
375
1' x 30'
30
450
1' x 35'
35
525
1' x 40'
40
600
1' x 45'
45
675
1' x 50'
50
750
1.5' x 37'
55.5
833
1.5' x 40'
60
900
1.5' x 44'
66
990
1.5' x 47'
70.5
1058
1.5' x 50'
75
1125
1.5' x 54'
81
1215
3' x 2'
6
90
3' x 5'
15
225
3' x 7'
21
315
3' x 30'
90
1350
240 VOlT ThEORETiCAl RESiSTAnCE ChART
lATiCRETE Floor hEAT 240V 15W SQFT
Product
SQFT
Power (W)
1.5' x 13'
19.5
293
1.5' x 20'
30
450
1.5' x 27'
40.5
608
1.5' x 33'
49.5
743
1.5' x 40'
60
900
1.5' x 47'
70.5
1058
1.5' x 53'
79.5
1193
3' x 30'
90
1350
3' x 35'
105
1575
3' x 40'
120
1800
3' x 45'
135
2025
3' x 50'
150
2250
Resistance (Ohm)
Current (Amps)
96
1.3
80
1.5
64
1.9
48
2.5
42
2.9
38
3.1
32
3.8
27
4.4
24
5.0
21
5.6
19
6.3
17
6.9
16
7.5
15
8.3
14
8.8
13
9.4
12
10.1
160
0.8
64
1.9
46
2.6
11
11.3
Resistance (Ohm)
Current (Amps)
197
1.2
128
1.9
95
2.5
78
3.1
64
3.8
54
4.4
48
5.0
43
5.6
37
6.6
32
7.5
28
8.4
26
9.4
8

STEP-BY-STEP inSTAllATiOn PROCEDuRES

STEP 1: PlAn ThE inSTAllATiOn
Prepare a detailed installation plan or obtain
one from your dealer/distributor. An online
project
layout tool is available at
www.laticrete.com/fw.
STEP 2: OBTAin MATERiAlS
Broom and Dustpan; LATICRETE
Floor HEAT
®
Mat(s);
Digital
Ohm
Meter;
Measure; Scissors;
Marker; Smooth-sided
Trowel or Rubber Float; Notched Trowel (for
tile installation); LATICRETE Wire Eye™
(recommended); Staple Gun (optional); Hot Glue Gun with Glue (optional)
STEP 3: PREPARE ThE FlOOR
Inspect and clean the subfloor or underlayment
surface carefully making sure to remove any
sharp edges or pointed objects that might
damage the heating element. Wipe down the
substrate with a sponge that is clean and damp.
STEP 4: KEEP ThE lABElS
Remove the White Output Label and the
Silver Output Sticker (the electrical description
label and sticker provided on each roll of
LATICRETE Floor HEAT) and keep them with the
installation information. These will be used to
label the leads and the system at the Circuit Panel after the installation is
complete.
STEP 5: TEST ThE SYSTEM RESiSTAnCE
Test and record element resistance of each mat
as described in the documentation procedures
outlined on page 5.
STEP 6: CuSTOMiZE ThE MAT(S)
To ensure proper installation and coverage, dry cut the LATICRETE Floor HEAT
mat to custom fit the room (according to the provided layout) before any
thin-set mortar is applied. Be careful not to damage or sever the wires.
Tape

Publicidad

Tabla de contenido
loading