D
A
A. Screws - 3.5 x 9.5 mm flat-head (4)
B. Face plate (30" x 12" [76.2 cm x 30.5 cm] shown)
C. Cabinet (30" x 12" [76.2 cm x 30.5 cm] shown)
D. Screws - 4.2 x 15 mm truss-head (2)
For cabinet size - 30" x 12" (76.2 cm x 30.5 cm)
Attach the
x
(71.8 cm x 27.3 cm) face panel (supplied
28
⁄
"
10 ¾"
1
4
with range hood) to the hood liner using four 3.5 x 9.5 mm
flat-head screws and two 4.2 x 15 mm truss head screws.
Tighten to secure.
Connect the lamp electrical connector.
Connect the Vent System
Vented Installations
1. Connect the vent system to the range hood vent opening.
Seal the connection with clamps.
Non-Vented (recirculating) Installations
1. Connect the vent system to the range hood vent opening.
Seal the connection with clamps.
2. Install charcoal filters. See the "Available accesories" section.
Complete Installation
1. Replace grease filters. See the "Range Hood Care" section.
B
C
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
2. Plug 3-prong power cord into a grounded 3-prong outlet
located inside the cabinet above the range hood.
3. Check the operation of the range hood fan and light. See
"Range Hood Use" section.
If range hood does not operate, check to see whether a
circuit breaker has tripped or a household fuse has blown.
Disconnect power and check wiring connections.
NOTE: To get the most efficient use from your new range hood,
read the "Range Hood Use" section.
10
WARNING