■ The grounded 3 prong outlet is to be located inside the
cabinet above the range hood at a maximum distance of
33
" (85.0 cm) from where the power cord exits the hood.
7
16
The grounded 3 prong outlet must be accessible after
installation of the range hood. See illustration.

Prepare Location

■ It is recommended that the vent system be installed before
the range hood is installed.
■ Before making cutouts, make sure there is proper clearance
within the ceiling or wall for vent fittings.
■ Making the cutout to the bottom of the cabinet may be easier
to do prior to mounting the cabinet to the wall.
1. Disconnect power.
2. Determine which venting method to use: roof, wall, or non
vented.
3. Select a flat surface for assembling the range hood. Place
covering over that surface.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
4. Using 2 or more people, lift range hood onto covered surface
Range Hood Cabinet Cutout
1. Use a saber saw or keyhole saw to cut out the cabinet
bottom inside the cabinet frame.
Frameless type cabinets require ¾" (1.9 cm) front lip
NOTE:
in the cabinet bottom. A ¾" (1.9 cm) thick filler strip (not
supplied) may be required for some types of cabinets. (See
Step 3 in the "Install Range Hood" section).
33
(85 cm)
7
16

Installation Instructions

GROUNDING INSTRUCTIONS
■ For a grounded, cord-connected range hood:
This range hood must be grounded. In the event of an
electrical short circuit, grounding reduces the risk of electric
shock by providing an escape wire for the electric current.
This range hood is equipped with a cord having a grounding
wire with a grounding plug. The plug must be plugged into an
outlet that is properly installed and grounded.
WARNING: Improper grounding can result in a risk of electric
shock.
Consult a qualified electrician if the grounding instructions are
not completely understood, or if doubt exists as to whether
the range hood is properly grounded.
Do not use an extension cord. If the power supply cord is too
short, have a qualified electrician install an outlet near the
range hood.
SAVE THESE INSTRUCTIONS
Cut out dimensions (without spacers)
"
1
2
A. Bottom of cabinet cutout
2. Complete cabinet preparation following the instructions for
your type of venting. Determine venting cutout locations and
cut out vent openings in the cabinets, walls and/or soffit.
7
"
3
4
(27.62cm)
28
" (72 cm)
3
8
10
"
7
8