Jandy VSFHP185DV2A Manual De Instrucciones página 10

Ocultar thumbs Ver también para VSFHP185DV2A:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Page 10
ENGLISH
Bad Install
Air Lock
Bad Install
90 degree elbow
Good Install
4x pipe diameter
Best Install
Sweep Elbows in/out
for maximum efficiency
2.
The unions on both the suction and discharge ports
simplify installation and service while eliminating
the possibility of leaks at threaded adapters.
3.
The pump must be connected to at least two
hydraulically-balanced main drains for each pool
pump suction line. Each drain (suction outlet)
assembly must be provided with covers and must
be listed or certified to the latest published edition
of ANSI
/ASME
A112.19.8, or its successor
®
®
standard, ANSI/APSP-16. The suction fittings of the
main drains must be at least three feet (1 m) apart
or at different planes. The suction fittings can be a
drain and skimmer, two drains, two skimmers, or a
skimmer with an equalizer line installed. Check the
local codes for proper installation.
Jandy
Variable-Speed Pumps
®
too close
into pump
|
Installation & Operation Manual
NOTE
To prevent entrapment, the system must be
built so it cannot operate with the pump drawing
water from only one main drain. At least two main
drains must be connected to the pump when it is in
operation. However, if two main drains run into a
single suction line, the single suction line may be
equipped with a valve that will shut off both main
drains from the pump.
4.
The piping must be well supported and not forced
together where it will experience constant stress.
5.
Always use properly sized valves. Jandy Diverter
Valves and Ball Valves typically have the best flow
capabilities.
6.
Use the fewest possible fittings and limit the use of
90 degree elbows. Each additional fitting or length
of pipe increases resistance to flow which makes
the pump work harder.
NOTE
If more than ten suction fittings are needed,
the pipe size must be increased.
7.
Every new installation must be pressure tested
according to local codes.
3.2.4
Adjustable Bases (VS FloPro
Only)
To replace an existing pump with different dimensions,
use the adjustable bases to correctly align the suction
and discharge ports with existing plumbing. The VS
FloPro base and spacers increase the total height of
the pump and the height of the suction side port of the
pump. See Figure 5 and Table 2.
No Base Required
Hayward
Super Pump
®
®
Pump
Pentair
®
SuperFlo
®
Height
Suction
Sta-Rite
®
SuperMax
®
Side
Height
Small Base
Hayward Super II™
Jandy PlusHP by Zodiac
®
Jandy Max HP by Zodiac
Small Base with Spacers
Pentair WhisperFlo
®
Sta-Rite Dyna-Glas™
Small Base + Large Base
Sta-Rite Max-E-Pro
®
Sta-Rite Dura-Glas
®
Sta-Rite Dura-Glas II
Optional
Sta-Rite Max-E-Glas
®
(Order R0546400)
Figure 5.
Base Configurations (VS FloPro Models
Only)
Models
TM

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vsfhp270dv2aVsphp270dv2a

Tabla de contenido