Installation And Lubrication; Parts And Maintenance - Ingersoll Rand 231C Serie Especificaciones Del Producto

Ocultar thumbs Ver también para 231C Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 9
Model(s)
231C
231C-2
231H Model A
231H-2 Model A
244A
244A-2

Installation and Lubrication

Size air supply line to ensure tool's maximum operating pressure (PMAX) at tool inlet. Drain condensate from
valve(s) at low point(s) of piping, air filter and compressor tank daily. Install a properly sized Safety Air Fuse
upstream of hose and use an anti-whip device across any hose coupling without internal shut-off, to prevent
hose whipping if a hose fails or coupling disconnects. See drawing 04581666 and table on page 2.
Maintenance frequency is shown in circular arrow and defined as h=hours, d=days, and m=months. Items
identified as:
1.
Air filter
2.
Regulator
3.
Lubricator
4.
Emergency shut-off valve
5.
Hose diameter
6.
Thread size

Parts and Maintenance

When the life of the tool has expired, it is recommended that the tool be disassembled, degreased and parts
be separated by material so that they can be recycled.
The original language of this manual is English.
Tool repair and maintenance should only be carried out by an authorized Service Center.
Refer all communications to the nearest Ingersoll-Rand Office or Distributor.
4
Sound Level dB (A)
(ISO15744)
Pressure (L
)
p
"K
"=3dB(A)
pA
99
99
94
94
93
93
Power (L
)
w
"K
"=3dB(A)
wA
110
110
105
105
104
104
7.
Coupling
8.
Safety Air Fuse
9.
Oil
10. Grease - during assembly
11. Grease - through fitting
Vibrations Level
(ISO8662)
m/s²
5.2
5.2
5.2
5.2
5.5
5.5
Form 04584819-Edition 2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

231h serie244a serie

Tabla de contenido