Fault Detection and Troubleshooting
Safety Measures
6
Fault Detection and Troubleshooting
6.1
Safety Measures
DANGER
ATTENTION
6.2
Notes on Troubleshooting
Please check first whether there is an operating fault. You can eliminate some faults on your own.
Service work should only be carried out by authorised specialists.
Defective components should only be replaced with original parts.
In the event of after-sales service and when ordering spare parts specify the data given in the rating plate.
Inspection and maintenance intervals depend on the use of the appliance. Consult your dealer's after-sales
service department.
Regular inspection and maintenance of the appliance prevent disruptions to operation and ensure safety.
6.3
Fault and Action Table
Fault
Appliance does not become warm;
indicator light does not come on.
Appliance does not become warm;
indicator light does not come on.
Appliance does not become warm;
indicator light does not come on.
Appliance does not become warm;
indicator light is on.
Appliance becomes warm; indicator
light does not come on.
4330000_A6
TE-2/V19-26, 27-33 | TE-2/VK19-26 | TEH-1/V19-26, 27-33 | TEH-2/V19-26, 27-33 | TEUH-1/VS19-26 | TEUH-2/VS19-26, 27-33 | TEUH-2/VC19-26
Hazardous electrical voltage
The electrical voltage may be considerably dangerous to limb and life of per-
sons and lead to injuries.
Before looking for faults, switch off the appliance at the mains. Pull out the
mains plug and insert it into the plug park provided.
Exposed springs
When pressing down the stacking platform manually, the springs are ex-
posed. Reaching into the gaps of the exposed springs may cause hand inju-
ries.
Never press the stacking platform down manually.
Be careful when hooking and unhooking the springs. When adjusting springs
on sharp edges, pay particular attention to the ends of the tension springs.
Possible cause
Defective building fuses.
Defective On / Off switch.
Defective lead or mains plug
Thermostat is defective.
Defective indicator light.
Action
Check fuse and repair, if necessary.
Switch off the appliance at the mains
and have it checked and repaired by
authorised specialist staff, if neces-
sary.
Switch off the appliance at the mains
and have it checked and repaired by
authorised specialist staff, if neces-
sary.
Take the appliance out of operation
and have it checked and repaired by
authorised specialist staff, if neces-
sary.
Take the appliance out of operation
and have it checked and repaired by
authorised specialist staff, if neces-
sary.
EBR/V19-26, 27-33 | EBRH/V19-26, 27-33 | EBRH-2/V19-26
Chapter 6
Page 35
Plate dispenser