INSTALLATION
D
escription of the adjustment potentiometer (activation time).
The adjustment potentiometer PT1 is located on the top left of the SAR-2PLUS unit
close to the programming led.
Allows adjustment of the relay activation time from 3 seconds to a maximun
of 60 seconds.
The potentiometer PT1 is factory set to the minimum.
Adjustment modes:
Additional call repeater mode:
With the potentiometer set to minimum, the output is activated only during the tone
call and with the potentiometer set to maximum is activated during the time of
call plus 45 seconds, reproducing the cadence of the call.
Relay for lock release mode:
The output activation time will range from 3 to 60 seconds depending on the PT1
potentiomenter adjustment.
Bus relay mode:
The output activation time will range from 3 to 60 seconds depending on the PT1
potentiomenter adjustment.
D
escription of the programming led.
The programming led is located on the top left of the SAR-2PLUS unit, close
to the adjustment potentiomenter PT1.

Programming led:

Off: Out of programming.
Blinking: Relay unit on programming (SW1-3 set to ON).
On: Programming finished.
E
nd of line (only V2Plus system).
Put the 120 ohm End of line resistor in the SAR-2Plus units
where the bus connection ends.
SAR-2PLUS
JP1
E.of LINE BUS
BUS
BUS
PLATEA V2PLUS
SW2
BUS IN BUS OUT
HZ
PA PB
PLATEA V2PLUS
SW2
BUS IN BUS OUT
HZ
PA PB
BUS
39
SAR-2PLUS
JP1
E.of LINE
BUS
BUS
R.1 20