Malfunction
Low material
delivery
The pump changes
cycles when
product outlet is
closed.
Continuous escape
of air through the
silencer when the
pump is shut down
(without outlet).
20. EC DECLARATION OF CONFORMITY FOR MACHINES
In accordance with Directive 2006/42/EEC
Manufacturer:
Address:
Hereby declares that the product:
Brand:
Product line:
It is in accordance with the Essential Safety Requirements set out in the Annex to Directive 94/9/EEC.
For compliance with the requirements, the product complies with the standards:
- Directive of the EC Machinery (2006/42/EEC)
Also is in conformity with the provisions of the following Directives:
- ATEX regulation (Directive 94/9/EEC)
Marked "X" All static electricity is discharged by the air ducts.
Air hoses should be "ANTISTATIC"
Also is in conformity with the provisions of the following Directives: UNE-EN-13463-1:2011,
UNE-EN ISO 12100:2012, EN 809, EN12621, EN12162 and EN 1127-1.
The complete technical documentation and service instructions for the product are available.
In Vitoria-Gasteiz, on 01/07/2014
Cause
Insufficient inlet or air pressure.
Clogged product outlet hose.
Suction hose loose or of small
diameter.
Antipulsations filter, absorption or
gun dirty.
Product valves dirty, stuck or
damaged.
Product inlet fittings or connec-
tions loose.
Valve seat or ball closed or faulty.
Valve O-ring damaged.
Damaged vessel joints of the
distributor.
Damaged distributor plate and/or
insert.
Damaged sliding O-rings.
Damaged O-rings of the ancho-
ring bolt.
SAGOLA S.A.
C/ Urartea, 6 · 01010 VITORIA-GASTEIZ (Álava) · SPAIN
SAGOLA
DM 1/300 - DM 1/400
II 2G X.
Repair
Open air inlet regulator.
Clean outlet hose or replace.
Tighten suction hose or fit hose of
adequate diameter for the
product to be used (depends on
its viscosity).
Clean or replace.
Clean valves or replace.
.
Firmly tighten connections.
Clean or replace.
Replace.
Replace.
Replace.
Replace.
Replace.
Signed: Technical Manager
Enrique Sánchez Uriondo
-29-