TO THE PURCHASER, OWNER AND STORE MANAGER
Please review these warnings prior to posting them in a prominent location for reference.
TO THE PURCHASER
Post in a prominent location the instructions to be followed in the
event that an operator smells gas. Obtain this information from your
local gas supplier.
FOR YOUR PROTECTION
DO NOT store or use gasoline or other flammable vapors and liquids
in the vicinity of this or any other appliance.
Do not spray aerosols in the vicinity of this appliance when it is in
operation.
Improper installation, operation, alteration, adjustments, service or
maintenance can cause property damage, injury or death. Read the
installation, operating and maintenance instructions thoroughly before
installing, operation, servicing this appliance.
Installation, maintenance and repairs should be performed by a Pitco
Authorized Service and Parts (ASAP) company technician or other
qualified personnel. Installation, maintenance or repairs by an
unauthorized and unqualified personnel will void the warranty.
Installation and all connections must be made according to local
codes in force. In the absence of local codes in North America, the
installation must conform with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54 or the Natural Gas and Propane Installation Code
CSA B149.1 as applicable. In Australia, the appliance must installed
in compliance with AS/NZS 5601.
During the warranty period if a customer elects to use a non-original
part or modifies an original part purchased from Pitco and/or its
Authorized Service and Parts (ASAP) companies, this warranty will be
void. In addition, Pitco and its affiliates will not be liable for any
claims, damages or expenses incurred by the customer which arises
directly or indirectly, in whole or in part, due to the installation of any
modified part and/or received from an unauthorized service center.
This appliance, when installed, must be electrically grounded in
accordance with local codes, or in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.2, as applicable
Adequate means must be provided to LIMIT the movement or this
appliance without depending on the gas or electrical cord connection.
Single appliances equipped with legs must be stabilized by installing
anchor straps. All appliances equipped with casters must be
stabilized by installing restraining chains.
DO NOT alter or remove structural material on the appliance to
accommodate placement under a ventilation hood.
If the appliance is equipped with a power cord and it is damaged, it
must be replaced by a Pitco Authorized Service and Parts (ASAP)
company technician, or a similarly qualified person in order to avoid a
hazard.
The power supply must be disconnected before servicing, maintaining
or cleaning this appliance.
The appliance is NOT jet stream approved. DO NOT clean the
appliance with a water jet.
DO NOT attempt to move this appliance or transfer hot liquids from
one container to another when the unit is at operating temperature or
filled with hot liquids. Serious personal injury could result if skin
comes in contact with the hot surfaces or liquids.
DO NOT use an open flame to check for gas leaks!
DO NOT sit or stand on this appliance. The appliance's front panel,
tank, splash back, tank cover, work shelf, drain board is not a step.
Serious injury could result from slipping, falling or contact with hot
liquids.
NEVER use the appliance as a step for cleaning or accessing the
ventilation hood. Serious injury could result from slips, trips or from
contacting hot liquids.
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
The oil/shortening level should NOT fall below the minimum indicated
level line at any time. The use of old shortening can be dangerous as
it will have a reduced flash point and be more prone to surge boiling.
WARNING
The contents of the crumb catch and/or filter pan of any filter system
must be emptied into a fireproof container at the end of the frying
operation each day. Some food particles can spontaneously combust
into flames if left soaking in certain oil/shortening materials.
WARNING
Completely shut the appliance down when shortening/oil is being
drained from the appliance. This will prevent the appliance from
heating up during the draining and filling process. Serious injury can
occur.
WARNING
This appliance is intended for indoor use only.
WARNING
DO NOT operate appliance unless all panels and access covers are
attached correctly.
WARNING
It is recommended that this appliance be inspected by a qualified
service technician for proper performance and operation on a yearly
basis.
WARNING
There is an open flame inside this appliance. The unit may get hot
enough to set nearby materials on fire. Keep the area around the
appliance free from combustibles.
WARNING
DO NOT supply the appliance with a gas that is not indicated on the
data plate. If you need to convert the appliance to another type of fuel,
contact your dealer.
WARNING
If gas flow to appliance is interrupted, or pilots extinguish, wait 5
minutes before attempting to relight the pilot to allow any residual gas
in appliance to dissipate.
WARNING
Ensure that the appliance can get enough air to keep the flame
burning correctly. If the flame is starved for air, it can give off a
dangerous carbon monoxide gas. Carbon monoxide is a clear
odorless gas that can cause suffocation.
WARNING
Never add oil to the appliance when it is at operating temperature.
Splashing hot oil can cause severe injuries.
WARNING
Never add water to hot oil. Violent boiling can occur causing severe
injury.
WARNING
This appliance is intended for professional use only and should be
operated by fully trained and qualified personnel.
WARNING
To avoid splashing of hot liquid when installed, this fryer must be
restrained either by the manner of installation, or with adequate ties to
prevent tipping.
WARNING
An appliance equipped with casters and a flexible gas line must be
connected to the gas supply with a quick disconnect device. In North
America, gas appliances equipped with casters must be installed with
connectors that comply with the Standard for Connectors for Movable
Gas Appliances, ANSI Z21.69.CSA 6.16 Latest Edition. This connection
should include a quick disconnect device that complies with the Standard
for Quick Disconnect Devices for Use With Gas Fuel ANSI Z221.41.CSA
6.9 Latest Edition. In Australia, an appliance equipped with casters and a
flexible gas line must be connected to the gas supply with a quick
disconnect device that complies with AS 4627. The hose must comply
with AS/NZS 1869 and be class B or D and have a restraining cable. The
restraining cable must not exceed 80% of the length of the flexible gas
line.