5.1.3

Mount accessories

To protect the end positions against uncontrolled overtravel:
• Check the necessity of proximity sensors (hardware limit switches).
If proximity sensors are used as limit switches:
• Preferably use proximity sensors with normally-closed function.
This protects against overtravel of the end position if the proximity sensor cable is broken.
If proximity switches are used as reference switches:
• Use proximity sensors that correspond to the input of the controller being used.
• Use proximity sensors with switch lug (è Assembly instructions of the accessory).
Mounting options of the proximity sensor
1)2)
in the slots
1
Switch lug
2
Slot for proximity sensor
1) For ELGA-TB-RF-F1, no slots available.
2) For ELGA-TB-M1/M2, mounting is possible only on the opposite side of the measuring system
3) Only for ELGA-TB-RF-F1.
Fig. 13
• Avoid external influences from magnetic or ferritic parts in the vicinity of the proximity sensors
(minimum distance of 10 mm from the slot nuts).
• Avoid contamination:
– Use slot covers in all unused slots
(è www.festo.com/catalogue).
– Connect sealing air. That is possible on all four sides of the
axis. To do this, remove the threaded pin 3 on the cover and
connect compressed air.
36
With sensor bracket
1
2
1)
With mounting kit
3
1
3
Sensor bracket
4
Mounting kit
Fig. 14
Festo – ELGA-TB-G/-KF/-RF – 1502c English
3)
1
4
3

Publicidad