1 IMPORTANT
•
The boiler's guarantee does not cover any damaged caused by the non-observance of any of these instructions.
•
This manual must be conserved and given to any new user.
• This appliance is not destined for use by anyone (including children) with reduced physical, sensorial or mental
capacities or those who do not know how to use the appliance, unless they are supervised or instructed by a
person responsible for their safety.
• Check that the voltage on the indicator plate of the boiler coincides with the voltage of the mains circuit to which it
is going to be connected.
• Any re-installation must be performed by qualified electricians.
The use of these boilers in the presence of gases, explosives or inflammable objects is prohibited.
The air inputs and outputs of the boiler ensure its correct operation and protect it from over-heating. They must
never be covered.
This boiler must be disconnected from the mains electricity before carrying out any internal repairs.
The boiler must not be installed directly below a power take-off point.
The boiler must be installed in such a manner that the switches or other controls cannot be touched by anyone
who is using the bath or shower.
The installation must be performed in accordance with current electricity regulations.
This appliance is destined to be permanently connected to a fixed installation. The power circuit of the boiler must
incorporate an omni-polar cut-off switch with a separation between the contacts of at least 3 mm.
The electricity supply circuit must incorporate a differential switch.
This boiler must be earthed.
All the models incorporate different safety elements. If one or more of them are activated, consult the section
PROBLEMS & SOLUTIONS.
In time, the presence in the air of smoke, dust and pollution may stain the walls and areas close to the appliance.
450
F
A B
C
D
E
80
200
245
285
355
435
535
UPS 25-40
P
(kPa)
H(m)
4
40
3
20
2
1
0
0
0
0.5
1.0
1.5
0
0
20
18
DIMENSIONS & CONNECTION
A cold water input 1/2"
B safety valve drain
C S.H.W. outlet 1/2"
D heating return 3/4"
3
830
8
E heating out 3/4"
0
F electrical connection
30
3
2.0
2.5
3.0
4.0
3.5
0.5
1
(l/min)
40
60
4.5
3
Q(m /h)
Working curves of the accelerator pump.
265
760
30
D
E
B
F
80
160
200
300
350
Gabarrón CM & CMX