The Timer cannot be activated if the intensive speed is
functioning.
The "clean air" function is activated by pressing key E
for 2 seconds when the appliance is switched off. This
switches the motor on for 10 minutes every hour at the
first speed. During functioning a rotary movement of the
peripheral segments must be visualised on the display.
When this time has passed the motor switches off and
the fixed letter "C" must be visualised on the display
until the motor re-starts after 50 minutes for another 10
minutes and so on. Press any key apart from the light
keys to return to normal functioning. Press key E to
deactivate the function.
• Active carbon/grease filter saturation:
- When display item C flashes, at a speed where it
alternates with the letter F (e.g. 1 and F), the grease
filters must be washed.
- When display item C flashes, at a speed where it
alternates with the letter A (e.g. 1 and A), the carbon
filters must be replaced.
After the clean filter has been positioned correctly, the
electronic memory must be reset by pressing button A
for approximately 5 seconds, until the indication F or A
shown on the display C stops flashing.
• COMMANDS: (Fig.14A) LUMINOUS the key symbols
are explained below:
A = LIGHT
B = OFF
C = SPEED I
D = SPEED II
E = SPEED III
F = AUTOMATIC STOP TIMER - 15 minutes
• If your appliance does not have the INTENSIVE speed
function, press key E for two seconds and it will be
activated for 10 minutes after which it will return to the
previously set speed.
When the function is active the LED flashes. To inter-
rupt it before the 10 minutes have expired press key E
again.
• By pressing key F for two seconds (with the hood
switched off) the "clean air" function is activated. This
function switches the appliance on for ten minutes every
hour at the first speed. As soon as this function is acti-
vated the motor starts up at the first speed for ten min-
utes, During this time key F and key C must flash at the
same time.
After ten minutes the motor switches off and the LED of
key F remains switched on with a fixed light until the
motor starts up again at the first speed after fifty min-
utes and keys F and C start to flash again for ten minutes
and so on.
By pressing any key for the exclusion of the hood light
the hood will return immediately to its normal functioning
(e.g. if key D is pressed the "clean air" function is deac-
tivated and the motor moves to the 2nd speed straight
away. By pressing key B the function is deactivated).
• Active carbon/grease filter saturation:
- When button A flashes at a frequency of 2 seconds,
the grease filters must be cleaned.
- When button A flashes at a frequency of 0.5 seconds,
the carbon filters must be replaced.
After the clean filter has been replaced, the electronic
memor y must be reset by pressing button A for
approximately 5 seconds, until the light on the button
stops flashing.
•COMMANDS:(Fig.14B)MECHANICAL_the key symbols
are explained below:
A = LIGHT
B = OFF
C = SPEED I
D = SPEED II
E = SPEED III
G = MOTOR WORKING indicator