20.3 - SERVICE REPORTING

The relay is activated when the cycle count set for the Service
request reaches
(Chapter 22.4): in this way it is possible to
0
activate a warning light.
20.4 – OPENING COMMAND
The relay is activated when the motor is controlled when opening:
in this way it is possible to activate secondary motors or send
synchronized signals with the movement of the main motor.
20.5 – CLOSING COMMAND
The relay is activated when the motor is controlled when closing:
in this way it is possible to activate secondary motors or send
synchronized signals with the movement of the main motor.

20.6 - SAFETY DEVICE TESTS

The relay is activated simultaneously with the relay dedicated to
the test of photocells: in this way it is possible to perform the
function test on devices that DO NOT use the 24 Vac power
supply on terminal E5, for example devices powered to 12 Vdc.

20.7 - CUSTOM

This feature is intended primarily for connecting warning light
devices.
Programming this parameter allows you to define the state of the
relay options selected in these 5 situations:
: closed gate, unit waiting for command
ATTES
:
opening gate
OPEN
: closing gate
CLOSE
: gate open and running count of the automatic
PAUSE
closing time
: gate open without counting the automatic
ARRES
closing time
To program proceed as follows:
1. Select the value
and press OK: the display shows
CUST
ATTES NO
h
i
2. Using the buttons
and
situation:
: relay contact open
NO
: relay contact closed
SI
3. Press the OK button to scroll through the available 5 situations
and select the status of the relay through the buttons
select the status of the relay in this
h
and

21 - ADI INTERFACE

The ADI (Additional Devices Interface) interface of the control
unit allows the connection to ERREKA optional modules.
Refer to ERREKA catalogue or to the technical sheets to see which
optional modules with ADI interface are available for this control
unit.
m
WARNING: Please read the instructions of each single
module to install the optional modules.
For some devices, it is possible to configure the mode for
interfacing with the control unit; in addition, it is necessary to
enable the interface so that the control unit can process the
signals arriving from the ADI device.
Please refer to the
I.ADI
interface and access the device configuration menu.
When the device is enabled, the display shows the word Adi at
the top right:
I1 I2 I3 I1
ADI devices use the display of the control unit to issue alarms or
display the configuration of the control unit:
• PHOTOCELL ALARM - the segment at the top turns on: the
gate stops, when the alarm ceases the gate restart in opening.
• RIBBON ALARM - The bottom segment turns on: the gate
reverses for 3 seconds.
• STOP ALARM - The lowest segment turns on: the gate stops
and cannot restart until the alarm is disabled.
• SLAVE - When you use a SYNCHRO module instead of
the word Adi,
SLV
configured as SLAVE
i
- 79 -
programming menu to enable the ADI
ATTESA
WAITING
I2 C1 C2
turns on to indicate when the unit is