Preparing The Light Fixture For Installation - Jandy Pro Serie Manual De Instalación Y Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Section 3. Installing Jandy
Pro Series Light
Fixture during New
Construction
WARNING
Risk of Electrical Shock or Electrocution.
underwater light must be installed by a licensed or
certified electrician or a qualified pool serviceman in
accordance with the National Electrical Code and all
applicable local codes and ordinances in the US, the
Canadian Electrical Code ("CEC" or C22.1) in Canada.
Improper installation will create an electrical hazard,
which could result in death or serious injury to pool or
spa users, installers or others due to electrical shock,
and may also cause damage to property.
Always disconnect the power to the light at the
circuit breaker before installing or servicing the light.
Failure to do so could result in death or serious injury
to serviceman, pool or spa users or others due to
electrical shock.
3.1
Preparing the Light Fixture for
Installation
NOTE
The electrician must complete preparatory steps
before light fixture is installed. See Figure 1.
Ensure that the pool meets the requirements of the
current National Electrical Code
the US, the Canadian Electrical Code ("CEC" or C22.1) in
. A licensed or certified electrician must install the
Canada
electrical system to meet or exceed those requirements
before the underwater light is installed. Some of the
requirements of the National Electrical Code, which the
pool electrical systems must meet, are as follows:
WARNING
To minimize risk of Electrical shock or electrocution,
which could result in injury or death, for supply
connection of low-voltage lights use only an isolating
low voltage power supply, evaluated and listed by a
Nationally Recognized Testing Laboratory (NRTL) for
swimming pool use.
1.
The lighting circuit must have a Ground Fault
Circuit Interrupter (GFCI) for 120 volt models,
and must have an appropriately rated circuit
breaker.
2.
The junction box (or, for 12 volt models, the low
voltage transformer) must be located at least eight
(8) inches above water level, at least four (4)
inches above ground level, and at least four (4)
feet from the edge of the pool. See Figure 1.
3.
The light fixture and all metal items within five
Jandy
Pro Series, White LED Lights
®
This
and all local codes
®
in
|
Installation Manual
(5) feet of the pool must be properly electrically
bonded to a reliable point of grounding.
4.
The wet niche must be properly installed so that
the top edge of the underwater light's lens is at
least 18 inches below the surface of the water in
the pool. See Figure 1.
5.
The wet niche must be properly electrically
bonded and grounded via the No. 8 AWG ground
connector located at the rear of the niche. See
Figure 1.
NOTE
To be certain that the pool's electrical system meets
all applicable requirements, the electrician should also
consult the local building department.
Use only approved wet niches (see following note) to
ensure a safe and proper installation.
NOTE
Jandy Pro Series lights are ETL listed (ETL report/
file 3141154CHI) for installation with only the following
manufacturer's wet niche fixtures:
Large Niche Model Numbers:
Jandy Pro Series: PLNICLRG, PLNICVFLRG,
WT000002, SSNICLRG1R, SSNICLRG1S
Pentair: 620004, 78210200 thru 700,
78210401, 79206700
Hayward DuraNiche: SP0600U
Sta-Rite: 05161-2352 thru 2369, 05163-2395
thru 2396
Small Niche Model Numbers:
Jandy Pro Series: PLNICSM, SSNICSM,
Pentair: 78241100, 78242200, 78242300
78243100 thru 300, 78244100 thru 300,
79206600
Hayward DuraNiche: SP0601U
Sta-Rite: 05166-1017 thru 1034, 05167-1035
thru 1037
Pentair
and Sta-Rite
are registered trademarks of Pentair, Inc.
®
®
Hayward
is a registered trademark and DuraNiche
®
Hayward Pool Products, Inc.
To GFCI, Circuit
Breaker and
Power Source.
48"
min.
4" min.
Rigid
Conduit
#8 AWG Ground
Connector bonding
is located at rear
of niche.
Figure 1.
Jandy Pro Series LED Light Installation
Page 5
ENGLISH
is a trademark of
8" min. Junction Box or Low
Voltage Transformer, to the
max water level of the pool.
18" min. to top of Lens.
Concrete must be cut
back around Niche to
allow for a compacted
plaster seal.
11.50"
Coil 4 ft. of light cable
around Fixture.
16"

Publicidad

Tabla de contenido
loading

Tabla de contenido