Operating Instructions
Installer:
This product has been
Please read all of the instructions
manufactured and 100% quality
before installation. This will help
tested.
you to be familiarized with all the
features and options available to
you with these devices.
Safety Warnings
L Disconnect the power supply
L Installing the sensor involves
before attempting any work
work on the line voltage power
on the sensor!
supply. This work must
L Before installation, make sure
therefore be carried out
that power has been switched
professionally in accordance
off at the breaker and check
with the applicable Nation
that the circuit is dead with
Electrical Codes and electrical
a voltage tester.
operating conditions.
Installation
(see page 3)
l
For indoor use only.
When mounting to the ceiling,
Mounts to a round 3.0 mud-ring
the ceiling mount adapter should
or can be mounted directly to
be used.
the ceiling or wall using anchor
bolts. Additionally, the sensor
can be mounted to the ceiling
using the supplied 1/2" snap in
chase nipple, washer and lock
nut.
System Components
a
e
Ceiling mount adapter
Light level setting
b
f
Sensor
Occupancy time
delay setting
c
Sensor settings cover plate
Switching output 1
d
Sensor DIP switch settings
g
HVAC stay-'ON' time
(1) Normal / Test mode
Switching output 2
(2) Manual 'ON' / Automatic
h
'ON' mode
HVAC switch-'ON' delay
(3) Momentary / Maintained
Switching output 2
switch option
i
Reach setting
(4) 'ON' only / 'ON'&'OFF'
(ultrasonic only)
manual switching
1 0
COM1-24 Wiring
.1
(5) Constant light level DIM
1 0
COM2-24 Wiring
control option
.2
(6)(7)(8)
1 0
COM2-24 Multiple Sensor
.3
Trigger mode
Wiring
(DT CM sensor only)
This will also assist you to
minimize installation time and
provide maximum energy savings
and trouble-free operation.
L Control output DIM-24
(0-10 V) must only be used
for connecting electronic
ballasts with an electrically
isolated 10V dimming
control input.
Accessories:
- RC 8 Service Remote
- RC 4 User Remote
- Smart Remote
1 0
DIM-24 Wiring
.4
1 0
DIM-24 Multiple Sensor
.5
Wiring
k
Mounting plate
l
Installation /
Dimensional Drawings /
Positioning / Coverage
Pattern / Recommended
Application
m
Stay 'ON' time DIM before
'OFF' option
n
Trigger mode options
o
Anchor bolts
p
1/2" Snap in chase, washer,
lock nut
- 10 -
How it Works / Basic Function
The Control Pro IR CM and DT CM
Lighting is controlled in relation to
presence detector product family
both the presence of motion and
is intended to control lighting and
ambient light levels. The HVAC
HVAC in commercial buildings,
output on the (COM2-24) is
schools, public building, etc.
signaled in relation to only the
presence of motion.
IR CM COM1-24
IR CM COM2-24
DT CM COM1-24
DT CM COM2-24
1 switching output (COM1-24 Low
1 low voltage switching output
Voltage) operating in relation to
operating in relation to the
the detection of motion and
detection of motion and ambient
ambient light level.
light level. An additional isolated
normally open and normally
Settings:
closed set of dry contact closures
- Light level setting
for signaling HVAC (heating/
- Occupancy time delay,
ventilation/air conditioning) in
Pulse mode, IQ mode
relation only to the presence of
- Ultrasonic reach setting
persons.
(DT CM only)
- Normal / Test mode
Settings:
- Manual 'ON' /
- Light level setting
Automatic 'ON' mode
- Occupancy time delay,
- Momentary /
Pulse mode, IQ mode
Maintained switch option
- HVAC stay-'ON' time
- 'ON' only /
- HVCA switch-'ON' delay,
'ON'&'OFF' manual switching
Auto-HVAC mode
- Trigger mode (DT CM only)
- Ultrasonic reach setting
(DT CM only)
- Normal / Test mode
- Manual 'ON' /
Automatic 'ON' mode
- Momentary /
Maintained switch option
- 'ON' only /
'ON'&'OFF' manual switching
- Trigger mode (DT CM only)
Commissioning adjustments are
made by potentiometer or dip
switch settings on the sensor or by
the optional (RC8 service remote)
commissioning tool.
IR CM DIM-24
DT CM DIM-24
1 low voltage switching output
operating in relation to the
detection of motion and ambient
light level. An additional isolated
0-10 volt dimming output
operating in relation to the
amount of daylight present.
Settings:
- Light level setting
- Occupancy time delay, IQ mode
- Stay 'ON' time DIM before 'OFF'
- Constant light level DIM
control option
- Ultrasonic reach setting
(DT CM only)
- Normal / Test mode
- Manual 'ON' /
Automatic 'ON' mode
- Momentary /
Maintained switch option
- 'ON' only /
'ON'&'OFF' manual switching
- Trigger mode (DT CM only)
- 11 -