A
MOUNTING
[1] Choose the optimal location: flat and large surface
[2] Mount the IB+ 4 DC Motor Controller WM
[3] Use cable tie!
[4] Keep to minimum distance
B
CABLING
[1] Tool for all terminals
[2] Wiring diagram
[3] Check the correct running direction of the end product
UP: the end product goes up ( C + )
STOP: the end product stops ( C + + )
DOWN: the end product goes down ( C + )
m To close window press UP, to open window press DOWN.
[4] Possible switches
1.
Smoove Origin IB, Ref. 1811272
2.
Double push button
[5] Local control
One local push button can control motors on several Motor Controller.
CHARACTERISTICS
Supply voltage
Power Supply
Stand-by current / Stand-by power (IEC 62301)
Max. motor current consumption
Supply voltage of group control input
Supply voltage of local push buttons
Terminals
Relay micro-gap
Running time per output
Operating temperature
Relative humidity
Material of housing
Housing dimensions (w x h x d)
Weight
Degree of protection
Protection class
Pollution degree
Conformity
CABLE
Connection to ...
Cable
Motors
Min.: 2 x 0.6 mm/22 AWG
Max.: 2 x 2.5 mm
Switch
Min.: 3 x 0.6 mm/22 AWG
Max.: 3 x 2.5 mm
IB+ bus
Min.: 4 x 0.6 mm/22 AWG
Max.: 4 x 1.5 mm
24 V DC
Min.: 2 x 1.5 mm
Max.: 2 x 2.5 mm
We care about our environment. Do not dispose of the appliance with usual household waste. Give it to an approved collection point for recycling.
m Control of non Somfy motors only on request and after approval by Somfy
24 V DC (min. 21.5 V - max. 28 V DC)
Regulated and short circuit proof power supply, certified and suitable for the connected motors
28 mA@24 V DC / 670 mW@24 V DC
4 x 2.5 A@24 V DC
SELV, 16 V DC
SELV, 16 V DC
Spring connectors
μ
Max. 5 minutes
0 ° C ... + 45 ° C
Max. 85 %
PC-ABS
180 x 255 x 61 mm
690 g
IP 20
2
www.somfy.com/ce
Twisted pair
/13 AWG
2
Recommended
/13 AWG
2
Recommended
/15 AWG
2
/15 AWG
2
/13 AWG
2
C
COMMISSIONING AND OPERATING
[1] Reset/Prog button
Is the access to the basic configuration of the Motor Controller.
[2] Selection of the push button ergonomic
Local push button ergonomics and the type of end products to be
preselected:
• Screen mode (SCR)
• Venetian blind, European mode
• Venetian blind, US mode (default mode)
1.
To toggle between modes, press shortly the Reset / Prog button.
Repeat until the LED, according to the desired configuration, lights up.
2.
Save and exit
[3] Factory RESET
[4] Learn running time/length
1.
Drive screen to upper end limit
2.
Press Stop until screen drives down on its own
3.
Press shortly Stop when lower end limit is reached
[5] Learn and recall intermediate position (IP)
1.
Recording
2.
Recalling
Max. length
100 m/330 ft
1000 m/3300 ft
10 m/33 ft
Stripping length
6 mm/0.24"
6 mm/0.24"
6 mm/0.24"
6 mm/0.24"
animeo IB+ 4 DC Motor Controller WM. Ref. 5138034A -