Output data
Type
E94xSxE0024
E94xSxE0034
E94xSxE0044
E94xSxE0074
E94xSxE0134
E94xSxE0174
E94xSxE0244
 Temperature in the control cabinet
Type
E94xSxE0024
E94xSxE0034
E94xSxE0044
E94xSxE0074
E94xSxE0134
E94xSxE0174
E94xSxE0244
EDK94ASH24 DE/EN/FR/ES/IT 8.0
Voltage
[V]
up to +45 °C
0 − 230/400/480
1.5/1.5/1.3
0 − 230/400/480
2.5/2.5/2.2
0 − 230/400/480
4.0/4.0/3.5
0 − 230/400/480
7.0/7.0/6.1
0 − 230/400/480
13.0/13.0/11.4
0 − 230/400/480
16.5/16.5/14.4
0 − 230/400/480
23.5/23.5/20.6
Power loss P
V
U
= 230 V
U
= 400 V
Lr
Lr
70
90
85
105
100
130
125
160
200
260
240
300
310
400
l
Technical data
Electrical data
Current [A]

up to +55 °C
1.1/1.1/1.0
1.9/1.9/1.7
3.0/3.0/2.6
5.3/5.3/4.6
9.8/9.8/8.6
12.4/12.4/10.8
17.6/17.6/15.5
[W] at a switching frequency of 4 kHz
U
= 480 V
when controller is inhibited
LN
100
120
145
180
290
340
450
4
Number of
phases

3
3
3
3
3
3
3
40