4. Refer to Fig. 4. Gently place the sensor onto the application site so that the "Masimo" label is visible.
Note: Ensure that the neck of the patient is relaxed and not stretched in any way
Note: Ensure that there are no skin folds under the sensor pad
5. Apply pressure all around the perimeter of the sensor to ensure the adhesive is secure to the patient's skin.
6. Refer to Fig. 5. Remove the two piece sensor liner from the top of the sensor.
7. Refer to Fig. 6. Remove the Anchor liner and attach the Anchor pad onto the skin of the patient's shoulder region and ensure that the
cable is loosely stretched.
Caution: Ensure that the cable is not tightly stretched, to prevent accidental detachment of the sensor due to patient movement.
Caution: The Anchor pad needs to be attached directly to the patient's skin in order to ensure correct readings.
8. Route the sensor cable towards the back of the patient.
Warning: Carefully route all patient cables to reduce the risk of patient entanglement or strangulation.
9. Refer to Fig. 7. Connect the sensor to the RAM dual cable.
10. Confirm that the pulse oximeter sensor is properly applied to the patient's application site and also connected to the RAM dual cable.
Note: The RAM dual cable must be connected to a compatible monitor with Masimo rainbow SET technology with the RRa feature
enabled.
11. Confirm that the monitor is able to detect respiratory signal (refer to device manual).
Note: If the respiratory signals are not detected, then select and alternate site on the neck using a new rainbow Acoustic RAS-45 sensor.
C) Removing the rainbow Acoustic RAS-45 sensor
1. Refer to Fig. 8. Disconnect the sensor from the cable.
2. Gently pull on the sensor adhesive tab to stretch and release the sensor from the application site.
3. Gently pull on the anchor pad to lift and remove the adhesive from the patient's shoulder.
Caution: Pull on the sensor adhesive in the same direction as hair growth to minimize possible discomfort.
COMPATIBILITY
This sensor is intended for use only with rainbow Acoustic Monitoring enabled devices containing Masimo rainbow SET technology
or pulse oximetry monitors licensed to use rainbow Acoustic compatible sensors. Each sensor is designed to operate correctly only
on the pulse oximetry systems from the original device manufacturer. Use of this sensor with other devices may result in no or
improper performance.
For Compatibility Information Reference: www.Masimo.com
WARRANTY
MASIMO WARRANTS TO THE INITIAL BUYER ONLY THAT THIS PRODUCT, WHEN USED IN ACCORDANCE WITH THE DIRECTIONS PROVIDED
WITH THE PRODUCTS BY MASIMO, WILL BE FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF SIX (6) MONTHS. SINGLE
USE PRODUCTS ARE WARRANTED FOR SINGLE PATIENT USE ONLY.
THE FOREGOING IS THE SOLE AND EXCLUSIVE WARRANTY APPLICABLE TO THE PRODUCTS SOLD BY MASIMO TO BUYER. MASIMO EXPRESSLY
DISCLAIMS ALL OTHER ORAL, EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR PARTICULAR PURPOSE. MASIMO'S SOLE OBLIGATION AND BUYER'S EXCLUSIVE REMEDY FOR BREACH OF ANY WARRANTY
SHALL BE, AT MASIMO'S OPTION, TO REPAIR OR REPLACE THE PRODUCT.

WARRANTY EXCLUSIONS

THIS WARRANTY DOES NOT EXTEND TO ANY PRODUCT THAT HAS BEEN USED IN VIOLATION OF THE OPERATING INSTRUCTIONS SUPPLIED
WITH THE PRODUCT, OR HAS BEEN SUBJECT TO MISUSE, NEGLECT, ACCIDENT OR EXTERNALLY CREATED DAMAGE. THIS WARRANTY DOES
NOT EXTEND TO ANY PRODUCT THAT HAS BEEN CONNECTED TO ANY UNINTENDED INSTRUMENT DEVICE OR SYSTEM, HAS BEEN MODIFIED,
OR HAS BEEN DISASSEMBLED OR REASSEMBLED. THIS WARRANTY DOES NOT EXTEND TO SENSORS OR PATIENT CABLES THAT HAVE BEEN
REPROCESSED, RECONDITIONED OR RECYCLED.
IN NO EVENT SHALL MASIMO BE LIABLE TO BUYER OR ANY OTHER PERSON FOR ANY INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL
DAMAGES (INCLUDING WITHOUT LIMITATION LOST PROFITS), EVEN IF ADVISED OF THE POSSIBILITY THEREOF. IN NO EVENT SHALL MASIMO'S
LIABILITY ARISING FROM ANY PRODUCTS SOLD TO BUYER (UNDER A CONTRACT, WARRANTY, TORT OR OTHER CLAIM) EXCEED THE AMOUNT
PAID BY BUYER FOR THE LOT OF PRODUCT(S) INVOLVED IN SUCH CLAIM. IN NO EVENT SHALL MASIMO BE LIABLE FOR ANY DAMAGES
ASSOCIATED WITH A PRODUCT THAT HAS BEEN REPROCESSED, RECONDITIONED OR RECYCLED. THE LIMITATIONS IN THIS SECTION SHALL
NOT BE DEEMED TO PRECLUDE ANY LIABILITY THAT, UNDER APPLICABLE PRODUCTS LIABILITY LAW, CANNOT LEGALLY BE PRECLUDED BY
CONTRACT.
NO IMPLIED LICENSE
The single-patient sensor is licensed under Masimo's patents for single-patient use only. Purchase or possession of this sensor confers no express
or implied license to use the sensor either with any device which is not an authorized device or separately authorized to use Acoustic Respiration
sensors, or in any way other than for single-patient use. 
By acceptance of this product, you acknowledge and agree that no license is granted for use of this product with more than a single patient. 
After single-patient use, discard sensor.
4
8995D-eIFU-0318