SYSTEM COMPONENTS

Only BriskHeat's approved termination, connection and splice kits should be used. Failure to do so will void warranties and agency
approvals. Installation instructions in each component kit should be followed regarding heating cable preparation and assembly. Make
end seals (terminations) and splice connections before making the power connections. It is recommended that all heating cables be
tagged as they are installed with a discrete circuit number. This will facilitate identification, components needed and electrical wiring
during later phases of the installation. Power connection kits utilize an adapter plate kit for installation on instrument tubing and tanks.
Installation instructions for mounting are included in each kit.
Connecting bus wires together will create an electrical short.
Power Connection Kit
Fiberglass Tape
Heater Cable
Insulation
Pipe Clamps
Heat Sink
Note: Heating cable power connections and end seals are required for each heating cable. Heating cable splices, tees, and
thermostats are used as needed.
®
© BriskHeat
Self Regulating Heating Cable
End Seal
In-line Splice
Heater Cable Loop
Tee Splice
Figure 11
Corporation. All rights reserved.
11

System Component Compatibility

SLCBL
SLMCBL
SLHCBL
Yes
SLCBLUC
Ordinary Locations and
No
No
Roof & Gutter
Yes
SLCBLUC-GF
Ordinary Locations and
No
No
Roof & Gutter
Yes
SLCBLKC
Ordinary Locations and
No
No
Roof & Gutter
Yes
SLCBLSK
Ordinary Locations and
No
No
Roof & Gutter
Yes
PTBO-GET
Yes
Yes
Hazardous Locations
Yes
JHE-GET
Yes
Yes
Hazardous Locations
Yes
JHS-GET
Yes
Yes
Hazardous Locations
Yes
JHT-GET
Yes
Yes
Hazardous Locations
SLCABUC
No
No
No
SLCABSK
No
No
No
SLCABKC
No
No
No
SLMCABUC
No
No
No
SLMCABKC
No
No
No
SLCABUC-CSA-M
No
No
No
SLCABEND-CSA-2
No
No
No
ROOFKIT
No
No
No
ROOFENDKIT
No
No
No
SLCABPWP-H
No
No
No
SLCABKC-H
No
No
No
®
© BriskHeat
Self Regulating Heating Cable
SLCAB
SLMCAB
SLHCAB
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Yes
Ordinary and
No
Hazardous Locations
Yes
Ordinary and
No
Hazardous Locations
Yes
Ordinary and
No
Hazardous Locations
Yes
No
Ordinary and
Hazardous Locations
Yes
No
Ordinary and
Hazardous Locations
Yes
Yes
Ordinary and
Ordinary and
Hazardous Locations
Hazardous Locations
Yes
Yes
Ordinary and
Ordinary and
Hazardous Locations
Hazardous Locations
Yes
No
SLCAB-BP only
Yes
No
SLCAB-BP only
Yes
No
No
Ordinary and
Hazardous Locations
Yes
No
No
Ordinary and
Hazardous Locations
Corporation. All rights reserved.
12
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No

Publicidad