Make sure that the deadman's handle does not become jammed.
Stop immediately if the system makes strange noises or displays aberrant behavior.
Stop immediately if the equipment leaks oil. Oil escaping under pressure can penetrate the skin and
cause serious injury. Go immediately to a hospital with a person who is injected with oil for medical
help. Give a specification of the oil to the medical staff.
Return inactive equipment immediately to the tool station.
Always adhere to the safety regulations that apply to other equipment that is used in the operation.
2.11
Safety regulations with respect to maintenance
Wear personal means of protection when performing maintenance tasks.
Never work in a way that could jeopardize safety.
Make sure that the equipment cannot roll away or tip over. The control and drive must be switched
off and safeguarded against unexpected activation.
Make sure that moving parts do not move unexpectedly.
Used or leaked fluids, and any other products consumed during the activities, must be collected and
disposed of in an environmentally responsible way.
3
Description
3.1
Equipment
This pump can be used independently because of the battery-drive hydraulic system.
The pump can run Holmatro tools that have been fitted with male CORE™ coupler.
The tools are produced as hand tools that can be operated by one person.
Its compact design and light weight make it easy for one person to carry. The electric motor runs a two-
stage pump that can build up a maximum pressure of 720 bar. The electric motor is driven by a 28 V
battery.
3.2
Type designation
GBP10EVO3
/i
Digit
Code
1-3
GBP
4-5
10
6-9
EVO3
3.3
Product identification
Refer to Fig. 2.
/i
1
Battery lock
2
Battery
3
Battery level indicator
4
Battery pack fitting
5
Hydraulic oil filler cap / drain plug
6
Pressure relief valve
GBP10EVO3
Description
Model indication of the pump
Type of pump
Battery driven
7
CORE™ coupler (female)
8
Switch cable
9
On/off switch (Fig. 5)
10
SOC indicator button
11
State Of Charge (SOC) indicator (see section 3.6)