Important: AYERBE GASOLINE generators have an oil level alert system that will automatically
shut off the engine before the oil level falls below the safety limit. However, in order to avoid having
it shut off unexpectedly, always check the oil before starting it.
AYERBE DIESEL GENERATING SETS have not this oil level alert system.
CHANGING THE OIL
1.Place the generator on a horizontal plane. Start the engine for several minutes to raise its temperature.
Then shut down the engine.
2.Take out oil dip stick.
3.Put an oil basin under the engine. Remove oil drain bolt.
Oil will be drained from tank.
4.Check oil drain bolt, dip stick and sealing gasket.
Replace immediately if damage is found.
5.Reassemble oil drain bolt.
6.Fill fresh oil up to within upper limit of dip stick scale.
FUEL GASOLINE GENERATORS
This generator is certified to operate with 95 octane and 98 octane unleaded gasoline. Unleaded
gasoline produces less build-up in the engine and on the spark plugs and extends the life of the
exhaust system.
It is very important to follow the safety regulations explained above.
In addition, you should keep in mind the following recommendations:
- Do not use bad or dirty gasoline or gas mixed with oil.
- Keep dirt or water out of the fuel tank.
- Do not use fuel with alcohol.
GROUDING THE GENERATOR
To ground the generator, use a 10 mm 2 copper wire attached to the generator's ground plug and a
galvanized steel ground rod 50 cm. into the ground. This ground plug also dispels static electricity
generated by electric machines.
4. STORAGE
If you aren't going to use the generator for a prolonged period of time, we recommend that you follow
the steps below:
- Store the generator in a clean, dry place.
- If you are not going to use the generator for six months, empty the oil tank, remove the oil
filter, and drain the fuel tank.
- Take out the injectors and pour a small amount of oil into the cylinders through the openings.
- Disconnect the battery if it has one
nergen PRO
1. Oil drain bolt
2. Sealing
gasket
3. Dip stick
27