6- INSTALLAZIONE
T80
2) OPTIONAL - CONTROL AND POWER UNIT:
Microprocessor control units (e.g.: Mod. TF) controlling a single actuator or several
actuators simultaneously by means of one or more manual push-buttons, an infrared
remote control or a 433 MHz radio control.
Rain sensors (RDC - 12V), the wind sensor (RW) and the brightness sensor (RL)
can be connected to these control units.
6.6-
EMERGENCY PROCEDURES
Should it be necessary to open the window manually due to a blackout or mechanism
failure, follow these instructions:
BEFORE WORKING ON THE ACTUATOR AND WINDOW, DISCONNECT THE
ACTUATOR FROM THE POWER SUPPLY AND SET ANY CONTROL DEVICE
SWITCHES TO "0" .
PADLOCK THE MAIN SWITCH OF THE SECTIONING DEVICE INSTALLED ON THE
MAINS LINE TO PREVENT ACCIDENTAL START-UPS. IF THE MAIN SWITCH CANNOT
BE PADLOCKED, PLACE A SIGN FORBIDDING OTHER PEOPLE FROM STARTING
THE DEVICE.
6.6.1- Single actuator
1) Fig. 13 - Unscrew the "D1" nut and remove the "V2" screw from the "SF" butterfly
bracket;
2) Open the window by hand.
6.6.2- Pair of actuators
IN APPLICATIONS WITH TWO MOTOR-DRIVEN DOORS, IN CASE OF BLOCK OF ONE
OR BOTH ACTUATORS, SIMPLY DISCONNECT POWER AND CONTACT THE
TECHNICAL SERVICE DEPARTMENT. IN THIS SITUATION DO NOT OPERATE THE
ACTUATORS AS YOU WOULD RISK DAMAGING THE SYSTEM.
IN CASE OF BREAKDOWN OF THE MOTOR-DRIVEN ACTUATOR, BEFORE
DISMANTLING IT PLACE THE DOOR SYSTEM IN SAFE CONDITION
1) Fig. 24 - Unscrew the "D4" nut and remove the "V6" screw from the "SF" butterfly
bracket;
2) Open the window by hand.
INSTALLATION AND USE INSTRUCTIONS
INSTALLATION -6
S.
EN
39