Brita PURITY 1200 Clean Manual De Instrucciones página 18

Ocultar thumbs Ver también para PURITY 1200 Clean:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
6.1 Removing the Filter Cartridge
Switch off the power supply of the terminal equipment (remove plug).
Close the inlet valve
Place the fl ush hose in a bucket and remove pressure from the fi lter system by
opening the fl ush valve
Note: If the escaping water is more than 1 litre, the inlet value
closed or is blocked with scale.
Stand on the kick loops
vessel lid
far as it will go.
Place the pressure vessel lid
Stand on the kick loops
vessel
Take your feet off the kick loops
hands on the mantle handles
Remove used fi lter cartridge
Place the used fi lter cartridge
drainage (> 5 min).
Lock the used fi lter cartridge
cartridge and return in the original packaging to the appropriate BRITA address listed
on the back of the cover.
6.2 Inserting the Filter Cartridge
16
at the inlet hose
6
. Collect waste water in the 10L bucket.
16
by pressing the lock
3
anti-clockwise by the mantle handles
1
and press the pressure vessel
9
.
11
from the pressure vessel
2
in the sink with the connection facing down for
2
with the transport protection cap
2
Check the O-ring seal of the new fi lter cartridge
the groove, dirt and damage. Note: The cartridge seat has been lubri-
cated with food-safe lubricant at the factory.
Check the connector seat of the fi lter cartridge O-ring
sure vessel lid
for dirt and damage.
3
Place new fi lter cartridge
Stand on the kick loops
whole turning clockwise until the mantle handles
loops
.
9
Stand on the kick loop
sel lid
on the pressure vessel
3
marking on the lid handle
Press the pressure vessel lid
lock engages
.
8
Switch on electrical power supply to the terminal device.
Execute the steps described under 5.3 to fl ush and bleed the new
fi lter cartridge
.
2
.
5
with both feet while opening the pressure
9
and turning it anti-clockwise as
8
vertically on the lid handle
3
with both feet while turning the pressure
9
1
in the pressure vessel
2
with both feet; lift the pressure vessel
9
with both feet and place the pressure ves-
9
. The positioning of the arrow
1
must line up with the "INSERT" groove.
14
down and turn clockwise until the
3
is not completely
6
.
14
as far as it will go.
11
down with both
1
.
of the new fi lter
12
for correct seat in
2
in the pres-
2
.
1
are over the kick
11
1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Purity 1200 clean extra

Tabla de contenido