1. Association Groups

The lock supports 2 association groups. Per Z-Wave Plus requirements, group 1 is
assigned to the Lifeline group and can only support 1 node.
The Lifeline group supports the following unsolicited messages:
Command Class
Command Class Battery
Command Class Door Lock
Command Class Notification
Command Class Device Reset Locally
Association group 2 is identified as the "Doorlock notify report" group. It allows at
most 5 other nodes to be associated with the lock and will provide all Notification
Reports, via the Command Class Notification, generated by the lock.

2. Configuration Parameters

The Z-Wave door lock module supports the use of the configuration command class to
provide advanced configuration of the door lock over the Z-Wave network. This section
describes the configuration parameters supported by the door lock.

2.1 Configuration Parameters 1 through 30

Parameter Name: User Code Type
Data Length: 1 byte
Default Value: 1 (Owner)
Possible Values: 0x01 (owner), 0x03 (Guest), 0x04 (Worker)
Description:
Configuration parameters 1 through 30 are a one byte field used to set the type of user for
their corresponding user code. The following table shows the valid values for user code
types:
Command
Battery Report
Door Lock Operation Report
Notification Report
Device Reset Locally Notification