LBC LRO-1G5 Instalación, Servicio Y Manual De Piezas página 28

Ocultar thumbs Ver también para LRO-1G5:
Tabla de contenido

Publicidad

Startup
1
Check voltage supplied to oven. Confirm it matches data plate.
Turn off manual gas valve. Install manometer in supply-side port of gas valve.
2
3
Check amp rating of breakers supplying power to oven and confirm they are within ratings on data plate.
Power oven up. Confirm function of roof-top ventilator.
4
Close loading door. Confirm that door switch has ample over-travel, open and closed and is driven past the trip point.
5
6
Check direction of rotation of blower motor. The motor must rotate counterclockwise when viewed from above (clockwise
from shaft end). NOTE: air will flow out of pressure panels even if blower operates backward, but oven will not bake
correctly.
Confirm that chamber vent lid seals tightly to vent intake duct.
7
8
Check pressure panel gap settings and confirm they match settings the manual.
Raise thermostat setting so oven will call for heat. Observe that heat sequence lights all turn on.
9
Open manual gas valve and cycle loading door. Observe that burner lights.
10
11
Check supply pressure to gas valve. Confirm that supply pressure is always between 5 and 14 inwc (both NG and LPG).
Cycle burner off and wait 5 minutes. Observe the burner lighting. When gas valve opens ("clicks"), flame must light and
reach sensor within 1 second.
Remove one filter from hood and confirm burner will still light. Replace filter.
12
Open loading door. Place an oven rack inside oven. Confirm that rack will have clearance to carrier when rack is heated
13
and when casters wear.
Close loading door. Confirm that top/side door seals are compressed and that door-floor seal is properly adjusted. Confirm
14
that door-to-header and door-to-jamb gaps are even and approx 3/8".
Heat oven to 350 deg F. Confirm that there are no hot spots around oven.
15
Perform test bake with aload of product. If no product is available, load oven with a full rack of sheet pans with 6 slices
16
ofwhite bread on each pan. Bake at 400 deg for 20 minutes. Check evenness of bake.
Confirm that rack is lifted clear of floor. Test all oven racks available.
17
Remove rack. Cycle loading door and check stop position of carrier. NOTE: Carrier stop position must only be adjusted with
18
oven at temperature and with no rack in oven.
19
Set oven to 400 deg F and allow it to preheat for 30 min. Set time to 20 min, steam to 10 sec and vent to Auto or 7 minutes.
Place a cold rack in oven and press start. Observe that there is ample steam on rack and that oven regains set point in 6 min
or less. Observe that the vent removes steam from oven at end of bake.
20
Measure Carbon Monoxide (CO) produced by oven. NOTE: CO measurement must not exceed 400ppm air-free. Less than
50ppm is normal. Confirm that loading door operates freely and will not close on operator.
Confirm that loading door operates freely and will not close on operator.
21
Inspect fit and finish of oven. Look for missing screws, protective plastic still on parts, scratches or dents, missing parts or
22
misalignment of panels.
Confirm that interior lights operate when door is open and oven is on.
23
Check for leaks in water, gas and drain lines.
24
Confirm that the operators manual is in the pocket inside the control compartment.
25
28