Electric Connections - Ribind T2 CRX Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ELECTRIC CONNECTIONS

POINT A - CONTROL PANEL FEATURES
ON
TR2
TR1
S3
J8
J5
JP1
JP2
JP3
J6
J3
J7
J2
JP17
J4
J1
J1
N -L1
Main power supply 230 Vac 50/60 Hz (120V/60Hz upon request)
J2
A+ TEST
Safety strip self-test power supply +24 Vdc
A +
Accessories power supply +24 Vdc
A -
Accessories power supply -24 Vdc
PHOT. NC
Photocells contact (NC)
EDGE NC
Safety strip contact (NC)
K BUTT.
Single pulse contact (NO)
PED. BUTT.
Pedestrian opening contact (NO)
COM
Common contact (common line for all the command and safety inputs)
LOCK
Electric lock connection (MAX 15W 12V)
AERIAL
Radio Antenna
J3
COM
Common contact (common line for all the command and safety inputs)
BUZZER
Buzzer contact (24 Vdc max 200 mA)
SIGNAL
Gate open state output indicator (24 Vdc 3W max)
J4
Flashing light (max 40W )
U - MOTOR 2
MOTOR 2 COMMON CONNECTION
V-W - MOTOR 2 MOTOR 2 PHASE AND CAPACITOR CONNECTIONS
U - MOTOR 1
MOTOR 1 COMMON CONNECTION
V-W - MOTOR 1 MOTOR 1 PHASE AND CAPACITOR CONNECTIONS
J5
DO NOT REMOVE ANY JUMPER! OTHERWISE THE OPERATOR WILL
NOT WORK!
SW T2
J6
SW RADIO
(only CRX control board) DO NOT REMOVE ANY JUMPER! OTHERWISE
THE OPERATOR WILL NOT WORK!
J7
PROBE
Terminal block to connect the heater sensor only for operator (code
AA14019).
J8
RADIO
Built-in radio module (model CRX), or connector for radio receiver RIB,
24 Vdc supply
JP17
To select 1 motor (M1) or 2 motors (M1 and M2)
S3
PROG
Programming button
TR1
TORQUE
Electronic torque regulator
TR2
LOW SPEED
Electronic regulator for low speed on approach motor (See chart 1)
21
T2
cod. AC07086
T2 CRX cod. AC07085
G
B

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

T2Ac07086Abt2001Abt2003Ac07085Abt2000 ... Mostrar todo

Tabla de contenido