Page 10
ENGLISH
6.2
To Reset to the Beginning of the Color
Sequence
Turn the light OFF, wait four (4) to five (5) seconds, then
turn ON, the light will return to the beginning of the color
cycle (Alpine White).
NOTE
If an AquaLink
RS control system is being used the
®
color set can be selected using the indoor controller.
NOTE
To synchronize colors on multiple Jandy Pro Series
WaterColors RGBW LED Light systems wired to
separate switches, perform the above actions on all
of their switches simultaneously. All Jandy Pro Series
WaterColors RGBW LED Lights will synchronize
automatically if activated by the same switch. No other
accessories are required.
Section 7. Replacing LED Board
and Driver (PCB)
WARNING
Always disconnect power to the color light at the
circuit breaker before servicing the light. Failure to do
so could result in death or serious injury to installer,
serviceman, pool or spa users or others due to
electrical shock.
1.
Turn off the main electrical switch or circuit
breaker, as well as the switch, which operates the
underwater light.
2.
Be sure to have the following items:
• A new lens gasket.
• A light driver board. See Table 2 for specification.
WARNING
Replace light driver with the same type. Failure to
replace the light driver with the same type will damage
the light assembly and may cause an electrical hazard
resulting in death or serious injury to pool or spa users,
installers, or others due to electrical shock, and may
also cause damage to property. Be sure the power is
switched OFF before removing or installing PCB. Allow
PCB to cool before replacing.
3.
To remove the light assembly, unscrew the special
pilot screw at the top of the face ring, remove
light assembly from niche and gently place
assembly on the deck. It is not necessary to drain
down the pool. See Figure 6.
Jandy
Pro Series, WaterColors RGBW LED Lights
®
Table 2.
Jandy Pro Series
Model
WaterColors
RGBW LED
Large Light
WaterColors
RGBW LED
Large Light
WaterColors
RGBW LED
Small Light
WaterColors
RGBW LED
Small Light
Be sure to keep the special pilot screw from this
underwater light. This screw mounts and electrically
grounds the housing securely to the mounting ring
and wet niche. Failure to use the screw provided could
create an electrical hazard, which could result in death
or serious injury to pool or spa users, installers or
others due to electrical shock.
7.1
Pool Clamp Removal.
1.
2
NOTE
7.2
1.
2.
3.
4.
5.
6.
|
Installation Manual
Light Specifications
Fixture
Voltage
12 Volt AC
120 Volt AC
12 Volt AC
120 Volt AC
WARNING
Loosen the Phillips head screws (six (6) for small
light, eight (8) for large light) to allow the bottom
clamp to be removed from the face ring assembly.
Do not remove the screws or the retaining rings.
The retaining rings prevent the screws from
falling free from the bottom clamp and also aid in
ease of assembly.
Remove the bottom clamp, the face ring
assembly, the glass lens, and the gasket from
the fixture. Remove the silicone gasket from
the lens. Refer to Section 9, Exploded View and
Replacement Parts.
Always install a new lens silicone gasket whenever
disassembling the light.
12V Small Light Driver (PCB)
Replacement
Remove both quick disconnect wires from the
PCB. Note that the black wire is connected to
ACN (TP-2) and the White wire is connected to
ACL (TP-1).
Remove two (2) nuts and two (2) washers.
Remove the light driver from the light fixture.
Apply thermal grease to the back of the new light
driver board.
Place new light driver into the fixture with the
orientation shown in Figure 7.
Secure the light driver with one (1) washer and
one (1) nut on the right side of the light driver.
Torque to 12 in-lbs.
Light Driver (PCB)
Part Number
R0739500
R0739400
R0785700
R0739600