ECOFOREST CANTINA SUPER Manual De Instalación Y Mantenimiento página 32

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4.11. Do not install the stove in a sleeping room.
4.12. Install a fire protection between the ground and the stove if the floor is a combustible material.
4.13. Security distances should be respected when the stove is installed in spaces where materials around it, be it
the construction material itself, the fuel or any other type of materials, are likely to be flammable. Ensuring a
better access to the stove for future maintenance or repair work is also worth considering.
A
Lateral wall.
Back
of
the
B
separation that allows visualizing the
label marking the stove.
C
1.5 x depth of stove.
D
Shelf.
E
Depth of stove.
4.14. Gas output must be located in a ventilated area, not in closed or half-closed areas e.g. garage, corridor, air
space of the house or places where gas may concentrate.
4.15. The external parts of the stove may reach high temperatures that might burn when touching; it is
recommended to use a non flammable grid to avoid risk of burn for children and old people.
The end of the gas outlet flex should remain higher than the stove's output. It is mandatory to install at least
two metres in length vertically to create natural current preventing smoke, odors or eventual cut of electric
supply.
The horizontal pipe must not be longer than 1 metre; greater lengths mean ash, condensation or corrosion
may build up in this area.
Faced with cut of electric supplies and unusual weather conditions (storms, strong winds) it is
recommendable to install an uninterruptible power supply (UPS) which we have available as an option. This
apparatus only feeds the exhaust vent.
4.16. Distances from doors, Windows, ventilation grids or air input to the house or building:
A
Distance from ventilation grid.
B
Distance from ventilation grid.
C
Lateral side of a window.
D
Top of a window.
E
Top of a door.
F
Lateral side of a door.
G
Adjacent wall.
H
Height from adjacent wall.
I
Adjacent building.
LOCATION AND SAFETY DISTANCES.
stove.
Minimum
≥ 80 mm
See dimensions
≥ 400 mm
See dimensions
SECURITY NORMS FOR GAS OUTPUT AND AIR INPUT.
1250 mm
1250 mm
2300 mm
≥ E
500 mm
500 mm
650 mm
650 mm
300 mm
650 mm
31
Drawing 4
Drawing 5

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hidro 24Hidro 16Cs 2012/08Hc 2015Hb 2015

Tabla de contenido