Main Supply
Voltage
Current type
Connected load
Protection (slow)
Type of protection
Protective class
Water connection
Max. feed temperature
Min. feed volume
Suck height from open container (68 °F/20 °C) ft (m)
Max. feed pressure
Performance data
Water flow rate
Operating pressure of water (using standard
nozzle)
Max. excess operating pressure (safety valve) psi (MPa)
Steam flow rate
Max. operating pressure for working with steam
(using steam nozzle)
Part no. of steam nozzle
Max. operating temperature of hot water
Working temperature steam operation
Detergent suck in
Burner performance
Maximum consumption of heating oil
Max. recoil force of hand spray gun
Nozzle size
Values determined as per EN 60355-2-79
Noise emission
Sound pressure level L
Uncertainty K
pA
Sound power level L
Hand-arm vibration value
Hand spray gun
Spray lance
Uncertainty K
Fuel
Fuel
Amount of oil
Oil grade
Dimensions and weights
Length x width x height
Typical operating weight
Fuel tank
Detergent Tank
20
Technical specifications
pA
+ Uncertainty K
WA
WA
HDS 5.0/30-4S Eb
V
208-240
Hz
3~ 60
hp
11
A
30
--
IPX5
--
I
°F (°C)
86 (30)
gpm (l/min)
5 (19)
1.6 (0.5)
psi (MPa)
87 (0.6)
gpm (l/min)
2.4-5.0 (9.1-19)
psi (MPa)
460-3000 (3.2-20.7) 460-3000 (3.2-20.7)
3300 (22.8)
gpm (l/min)
2.4 (9.1)
psi (MPa)
580 (4.0)
--
2.885-041.0
°F (°C)
175 (80)
°F (°C)
311 (155)
gpm (l/min)
0-0.3 (0-1.2)
hp (BTU/h)
137 (349,000)
kg/h (gph)
8.2 (2.52)
N
42
--
062
dB(A)
71
dB(A)
2
dB(A)
88
m/s
2
1.0
m/s
2
3.6
m/s
2
1.0
--
Fuel oil EL or Diesel Fuel oil EL or Diesel
gal (l)
0.26 (1.0)
--
SAE 90
in (mm)
52.5 x 29.5 x 41.5
(1330 x 750 x 1060)
lbs (kg)
392 (178)
gal (l)
6.6 (25)
gal (l)
2.6+5.3 (10+20)
– 13
EN
HDS 5.0/30-4S Ec
460-480
3~ 60
11
15
IPX5
I
86 (30)
5 (19)
1.6 (0.5)
87 (0.6)
2.4-5.0 (9.1-19)
3300 (22.8)
2.4 (9.1)
580 (4.0)
2.885-041.0
175 (80)
311 (155)
0-0.3 (0-1.2)
137 (349,000)
8.2 (2.52)
42
062
73
2
90
1.2
5.2
1.0
0.26 (1.0)
SAE 90
52.5 x 29.5 x 41.5
(1330 x 750 x 1060)
392 (178)
6.6 (25)
2.6+5.3 (10+20)