6.7- Complete procedure for learning the travel for automatic gate systems with double swing leaves, without encoder.
The complete procedure allows saving the travel, with the ability to customize the slowdown distance and the offset both when opening and closing the 2
motors
- Press learning push-button P2 and keep it pressed
- The DL6 LED starts flashing
- Do not release the P2 button and hold it down for another 2 seconds
- The DL6 LED starts flashing faster
- Release push-button P2
- Activate APCH: M2 closes at normal speed, until the mechanical stop
- M1 closes at normal speed, until the mechanical stop
- Part M1 opening at normal speed
- When you want the gate to move more slowly activate APCH
- The slow speed phase begins for motor M1.
- When M1 reaches the mechanical stop, the second gate leaf M2 will open at normal speed
- When you want the gate to move more slowly activate APCH
- The slow speed phase begins for motor M2.
- When the gate leaf reaches the mechanical stop, the second gate leaf M2 will start closing at normal speed
- When you want the gate to move more slowly activate APCH
- The slow speed phase begins for motor M2.
- When the gate leaf reaches the mechanical stop for closing: the first gate leaf M1 will start closing at normal speed
- When you want the gate to move more slowly activate APCH
- The slow speed phase begins for motor M1.
- When the gate leaf reaches the mechanical stop for closing, the first gate leaf M1 will start opening and as soon as you decide that the gate leaf offset time
is sufficient activate APCH again: the second gate leaf will M2 start opening
- When the 2 gate leaves have completed opening, M2 will start closing as soon as you decide that the gate leaf offset time is sufficient activate APCH again:
the first gate leaves M1 will start closing.
- When the 2 gate leaves have completed closing, the DL6 LED will turn off to confirm successful programming.
N.B.: With this type of programming the mechanical stops are necessary when closing both during programming and in normal operation.
6.8- Complete procedure for learning the travel for automatic gate systems with a single swing leaf, without encoder.
The complete procedure enables saving the travel, with the ability to customize the slowdown distance.
- Connect the motor to terminals 1 and 2 (output for motor M1), the control panel automatically configures itself for single leaf operation.
- Press learning push-button P2 and keep it pressed
- The DL6 LED starts flashing
- Do not release the P2 button and hold it down for another 2 seconds
- The DL6 LED starts flashing faster
- Release push-button P2
- Activate APCH: M1 closes at normal speed, until the mechanical stop
- Part M1 opening at normal speed
- When you want the gate to move more slowly activate APCH
- The slow speed phase begins for motor M1.
- When M1 reaches the opening mechanical stop
- The first gate leaf M1 closes at normal speed
- When you want the gate to move more slowly activate APCH
- The slow speed phase begins for motor M1.
- When the gate leaf has completed closing, the DL6 LED will turn off to confirm successful programming.
N.B.: With this type of programming the mechanical stops are necessary when closing both during programming and in normal operation.
6.9- Programming or deleting remote controls
Save the remote control button to control the AP/CH input: press the P3 button until the DL6 LED with a green light begins to flash slowly, release the
button and press the button on the remote control to save, the DL6 LED comes on with a green light for 1 second to confirm saving. To save other remote
controls, repeat the above procedure.
Save the remote control button to control the APED input: press the P3 button until the DL6 LED with a green light begins to flash quickly, release the
button and press the button on the remote control to save, the DL6 LED comes on with a green light for 1 second to confirm saving the remote control button
for operating pedestrian opening. To save other remote controls, repeat the above procedure.
To delete a saved remote control: press the P3 button until the DL6 LED with a green light begins to flash very quickly, release the button and press the
button on the remote control to delete, the DL6 LED comes on with a green light for 1 second to confirm deleting the remote control button. To delete other
remote controls, repeat the above procedure.
To delete all the remote controls: cut off the power to the control panel, also disconnect any batteries.
Press and hold down the button P3, reconnect the power supply to the control panel without releasing the button P3 until the DL6 LED goes out.
The maximum capacity is 200 radio controls, on reaching the maximum capacity being saved on the remote control (the green DL6 LED flashes), on pressing
the button of the new transmitter to be saved, the green DL6 LED makes 3 quick flashes to indicate the memory is saturated.
N.B. The first saved remote control configures the control panel to accept only remote controls with a rolling code or only remote controls with a
fixed 12-bit code.
24
EN