Setting The Wind Sensor; Activating Automatic Reopening - FAAC TM2 X SW Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54

SETTING THE WIND SENSOR

The wind level point can be set using the button provided in the lower part of the
TM2 X SW sensor, identified by the windsock symbol. The speed can be set from a
minimum of 7,5 Km/h to a maximum of 45 Km/h.
It's prudent not to set the wind speed over the fourth level, which corre-
sponds to 35 Km/h.
"WIND-SPEED"
SETTING.
Following a wind alarm, the motor closes automatically the awning, overriding
user commands until the wind alarm passes. To deactivate the wind alarm, it's
necessary that the wind speed remains below the set level for at least 8 minutes.
After these 8 minutes the awning returns to the position it was in before the alarm,
if the automatic reopening function is active. This pause time is included to ensure
awning protection and to prevent continuous motor movement in the event of
sporadic gusts of wind.

ACTIVATING AUTOMATIC REOPENING

- only with TM2 ERY -
With the automatic reopening system, at the end of the wind alarm, the awning
opens again. From factory this function is not activated in the motor, but can be
easily activated with the following command sequence:
Tn: Already programmed remote control
+
A
B
Tn
TM2 X SW
MAXIMUM RECOMMENDED SPEED
FOR THE WIND-ALARM (35 km/h)
C
Tn
23
C
Tn (2 sec)
A4518_6H80_Rev.A