Technical Data - Victron energy Ph 12/180 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3. Technical data

12 Volt
Phoenix Inverter
24 Volt
48 Volt
Cont. AC power at 25 °C (VA)
(3)
Cont. power at 25 °C / 40 °C (W)
Peak power (W)
Output AC voltage / frequency
Input voltage range (V DC)
Low battery alarm (V DC)
Low battery shut down (V DC)
Low battery auto recovery (V DC)
Max. efficiency 12 / 24 / 48 V (%)
Zero-load power 12 / 24 / 48 V (W)
Zero-load power in Power Saving mode
Protection
(2)
Operating temperature range
Humidity (non condensing)
ENCLOSURE
Material & Colour
Battery-connection
Standard AC outlets
Other outlets (at request)
Protection category
Weight (kg / lbs)
Dimensions (hxwxd in mm)
(hxwxd in inches)
ACCESSORIES
Remote control panel
Remote on-off switch
Automatic transfer switch
STANDARDS
Safety
Emission / Immunity
3. Description of the Digital Multi Control panel
1. Battery cables of 1.5 meter (12/180 with cigarette plug)
2. Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
3. Non linear load, crest factor 3:1
12/180
24/180
48/180
180
175 / 150
350
110VAC +/- 5% or 230VAC +/- 3%
50Hz or 60Hz +/- 0,1%
10,5 - 15,0 / 21,0 - 30,0 / 42,0 - 60,0
11,0 / 22 / 44
10,5 / 21 / 42
12,5 / 25 / 50
87 / 88 / 89
89 / 89/ 90
2,6 / 3,8 / 4,0
3,1 / 5,0 / 6,0
n. a.
a - e
-20 to +50°C (fan assisted cooling)
max 95%
aluminium (blue Ral 5012)
1)
IEC-320 (IEC-320 plug included), Schuko,
or Nema 5-15R
United Kingdom, Australia/New Zealand
IP 20
2,7 / 5,4
72x132x200
72x155x237
2.8x5.2x7.9
2.8x6.1x9.3
n. a.
Two pole connector
Filax
EN 60335-1
EN55014-1 / EN 55014-2
12/350
24/350
48/350
350
300 / 250
700
n. a.
1)
3,5 / 7,7
n. a.
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ph 24/180Ph 48/180Ph 12/350Ph 24/350Ph 48/350

Tabla de contenido