NOTE: Water-cooled WG systems have an integral water regulating
valve which may close when wine cellar temperatures are satisfied
and the unit turns off. A water bypass loop or pump control circuit
may be required for proper system operation.
B. Upon start up the display will read " Hi Temp" fault. Press the
"Up" or "Down" button on the controller to go to the main screen. The "Hi
Temp" fault will remain illuminated on the main screen until the tempera-
ture within the wine cellar falls below 65°F (13°C).
C. The system will turn on after a 5-minute time delay and the cold air
section will start to deliver cold air. Contact Wine Guardian if the system
fails to turn on.
petitors' wine cellar air conditioning system.
Temperature/Humidity Remote Sensors - Sense and con-
trol multiple locations (maximum of three) within your wine
cellar. Ideal for odd shaped rooms or multi-room applications.
5. Installing Ductwork continued
Slip the ductwork over the end of the duct collar and
fasten using two tie wraps supplied with the kit making
sure the ductwork is tight on the duct collar.
C. Fold the insulation back over the duct and duct
collar and secure to collar using duct tape.
6. Water-Cooled Versions Only
A. Connect cooling water inlet and outlet pipes to cool-
ing water source. Closed loop cooling tower, lake wa-
ter, or geo-thermal water source systems are recom-
mended.
7. Turn Unit On
A. Turn the ON/OFF switch to the " ON" position.
Switch should turn green. The Remote User Interface
is preset to a wine cellar temperature of 55°F (13°C).
8. Optional Equipment
Humidification (Integral or Standalone) - Designed to
increase humidity levels in any size commercial or resi-
dential wine cellar. The integrated version can only be
mounted to a WG system. The freestanding version can
be used with WG Through-the-Wall systems or any com-
Duct Collar Connections - Wine Guardian duct collars
and duct kits are specifically designed to attach directly to
the WG unit with no additional drilling or tapping required.
Kit includes duct collars, flexible duct, tie wraps and fasten-
ers.