7- Programación Completa - Vimar ELVOX RS10 Manual Para El Conexionado Y El Uso

Ocultar thumbs Ver también para ELVOX RS10:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
RS10
The control unit can work with or without an encoder. When switching on, the control unit checks for the presence of the encoder on connector CN6. For
operation without an encoder it is necessary to insert the jumper in connector CN6 as shown in the image fig.4 and power up the control unit. With this
configuration, the obstacle detection function and parameter P16 are not active. For operation with an encoder, it is necessary to insert the cable of the
encoder circuit in the connector CN6 and power the control unit.
Fig. 4
3 . 1 W iring f or pow er line, f lash ing ligh t and electric motor:
Fig. 5
3 . 2 W iring f or 2 4 V outputs:
Second radio channel or photo-test output
Output for viewing gate movement
N umb er
D escription
1-2 -3
P ow er supply line
4 -5
O utput f or f lash ing ligh t
6 -7 -8
O utput f or pow ering th e electric motor
Second radio ch annel or ph oto-test
9 -11
output
10-11
G ate mov ement w arning output
11-12
2 4 V dc output to pow er accessories
CN6
230 Vac
ELA3
-
- -
+
F unction
Power line 230 V ac (1 = phase / 2 = ground wire / 3= neutral)
Output for flashing light (230 V a.c. max 40 W)
Output powering the motor (6 = common / 7 = opens / 8 = closes) the capacitor is con-
nected in terminal 7 and 8 in parallel with the electric motor
Second radio channel or photo-test output (selectable with parameter P08, max. 65 mA)
Gate movement warning output (selectable with parameter P07, max. 65 mA)
24 V dc output to power photocells and accessories (11 = GND / 12 = +24 Vdc max 300
mA)
EN
M
24Vdc output to power photocells and accessories
19

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Elvox rs10

Tabla de contenido