CASCADE INSTALLATION DIAGRAM - EXAMPLE 1
NOTE: The diagram in question is an example of the management potential of the control box; for further information, please refer to the
technical/commedrcial documentation.
Low Temperature circuit 1
A
Low Temperature circuit 2
B
Direct circuit
C
DHW boiler
D
Solar integration circuit
E
Domestic cold water
AFS
Domestic hot water
ACS
1 Control box
2 CoCo Communication interface
3 External probe 5kOhm@25°C (optional)
4 Hydraulic separator external probe (5kOhm@25°C)
5 Zone control thermostat
6 Safety thermostat area 1
7 Non-return valve
8 Heating circuit circulator 1 (230V – 50Hz)
9 Heating circuit probe 1 (5kOhm@25°C)
10 Heating circuit mixer valve 1 (230V -50Hz)
3
2
SCHÉMA D'INSTALLATION EN CASCADE - EXEMPLE 1
REMARQUE : Le diagramme en question est un exemple du potentiel de gestion de la boîte de contrôle ; pour plus d'informations, merci
de se référer à la documentation technique/commerciale.
A
Circuit basse température 1
B
Circuit basse température 2
C
Circuit direct
D
Chaudière ECS
E
Circuit d'intégration solaire
Eau froide sanitaire
AFS
ACS
Eau chaude sanitaire
1 Boîtier de contrôle
2 Interface de Communication CoCo
3 Sonde extérieure 5kOhm@25°C (option)
4 Sonde extérieure de séparateur hydraulique (5kOhm@25°C)
5 Thermostat de contrôle de zone
6 Zone de thermostat de sécurité 1
7 Clapet de non-retour
8 Circulateur de circuit de chauffage 1 (230V – 50Hz)
9 Sonde de circuit de chauffage 1 (5kOhm@25°C)
10 Vanne mélangeur circuit de chauffage 1 (230V -50Hz)
11 System shut-off valve
12 Safety thermostat area 2
13 Heating circuit circulator 2 (230V – 50Hz)
14 Heating circuit probe 2 (5kOhm@25°C)
15 Heating circuit mixer valve 2 (230V -50Hz)
16 Direct circuit circulator (230V – 50Hz)
17 Boiler circulator (230V – 50Hz)
18 Boiler higher probe (5kOhm@25°C)
19 Boiler lower probe (5kOhm@25°C)
20 Solar collector circulator (230V – 50Hz)
21 Solar collector probe (PT1000)
22 System fi lter
23 Expansion tank
NOTES: For cascade operating it is necessary to confi gure the
boilers.
For setting the parameters please refer to the electrical paragraph.
5
12
6
7
7
13
8
14
9
15
10
A
11
11
11
4
22
23
11 Vanne d'arrêt du système
12 Zone de thermostat de sécurité 2
13 Circulateur de circuit de chauffage 2 (230V – 50Hz)
14 Sonde de circuit de chauffage 2 (5kOhm@25°C)
15 Vanne mélangeur de circuit de chauffage 2 (230V -50Hz)
16 Circulateur de circuit direct (230V – 50Hz)
17 Circulateur de chaudière (230V – 50Hz)
18 Sonde supérieure de chaudière (5kOhm@25°C)
19 Sonde inférieure de chaudière (5kOhm@25°C)
20 Circulateur de collecteur solaire (230V – 50Hz)
21 Sonde de collecteur solaire (PT1000)
22 Filtre du système
23 Vase d'expansion
NOTES: Pour un fonctionnement en cascade, il est nécessaire de
confi gurer les chaudières.
Pour régler les paramètres, consulter le paragraphe électrique.
31
1
5
5
7
16
C
B
11
11
11
11
17
11
EN
21
ACS
18
7
E
20
11
D
23
19
AFS
11
23
fi g. 14
FR