STORAGE & MAINTENANCE
through the system. Allow process to continue for 2-4 hours (Consult
deliming agent package directions for exact time).
4. Once process is complete, turn off engine. Drain and clean the float
tank, remove the nylon stocking, and clean the gun and wand assembly.
5. Flush the entire system with clean, fresh water and place the nozzle in
the wand assembly.
6. Dispose of deliming solution according to local, state, and federal
regulations.
TEST VOLTAGE AND AMP DRAW - Use a voltmeter and amp meter to
test the machine for correct voltage and amperage. If you do not have
these instruments or are unsure of how to perform these tests, this proce-
dure should be performed by an authorized service technician.
INSPECT BURNER FUEL PUMP INTERNAL FILTER – This procedure
should be performed by an authorized service technician.
CHECK BURNER ELECTRODES - This procedure should be performed
by an authorized service technician.
REPLACE FUEL NOZZLE - This procedure should be performed by an
authorized service technician.
MAINTENANCE – SEASONAL
NOTE: Proper winterizing is based on the recommended manufacturer's
instructions listed on the "Protection Chart" shown on the back label of
most antifreeze containers.

WINTERIZING

For storage and transportation purposes in subfreezing ambient tempera-
tures, it will be necessary to winterize this unit. This unit must be protect-
ed to the lowest incurred temperature for the following reasons:
1. If any part of the pumping system becomes frozen; excessive pressure
may build up in the unit which could cause the unit to burst resulting in
possible serious injury to the operator or bystanders.
2. The pumping system in this unit may be permanently damaged if frozen.
FREEZE DAMAGE IS NOT COVERED BY WARRANTY.
If you must store your unit in an area where the temperature may fall
below 32°F, you can protect your unit by following one of the procedures
listed below.

AIR BLOWOUT

1. Remove the nozzle from the wand assembly. Squeeze the trigger until
water ceases to exit the wand assembly.
2. Connect an air fitting from an air hose to the inlet swivel or strainer fitting
in the float tank.
3. Run compressed air into the system to remove all water from the system.
Operator's Manual
WARNING
RISK OF UNIT BURSTING.
DO NOT STORE / OPERATE
U N I T
I N
A
F R E E Z I N G
ENVIRONMENT!
32˚F
0˚C