4 - SWITCHING ON AND OPERATION
4.1 Switching on the appliance
Every time the appliance is powered up, a series of data is shown on the
display including the flue gas sensor meter reading (-C- XX) (see para-
graph 4.3 - fault A09); the automatic purge cycle then starts, lasting around
2 minutes. During this phase, the three LEDs light up alternately and the
symbol
is shown on the monitor (fig. 25).
To interrupt the automatic purge cycle proceed as follows:
access the electronic board by removing the housing, turning the instru-
ment panel towards you and opening the board casing (fig. 16)
Then:
- press the CO button (fig. 26).
Live electrical parts (230 V AC).
To start up the boiler it is necessary to carry out the following operations:
- power the boiler
- open the gas tap to allow the flow of fuel
- set the room thermostat to the required temperature (~20°C)
- turn the mode selector to the desired position:
Winter mode: by turning the mode selector (fig. 27) within the area mar-
ked + and -, the boiler provides hot water for heating and, if connected to
an external storage tank - supplies hot water for DHW.
If there is a heat request, the boiler switches on and the boiler status indi-
cator LED lights up with a fixed green light. The digital monitor indicates
the heating water temperature, the icon to indicate heating and the flame
icon (fig. 29).
If there is a domestic hot water request, the boiler switches on and the
boiler status indicator LED lights up with a fixed green light.
The digital display shows the hot water system temperature, the icon to
indicate the hot water supply and the flame icon (fig. 30)
Adjustment of the heating water temperature
To adjust the heating water temperature, turn the knob with symbol
(fig. 27) within the area marked + and -.
Depending on the type of system, it is possible to pre-select the suitable
temperature range:
- standard systems 40-80°C
- floor systems 20-45°C.
For further details, consult the "Boiler configuration" section.
Adjusting heating water temperature with an external probe connected
When an external probe is connected, the value of the delivery tempera-
ture is automatically chosen by the system which rapidly adjusts ambient
temperature to the changes in external temperature. To increase or decre-
ase the temperature with respect to the value automatically calculated by
the electronic board, turn the heating water selector (Fig. 12.6) clockwise
to increase and anticlockwise to decrease. Adjustment settings range from
comfort levels - 5 to + 5 which are indicated on the digital display when the
knob is turned.
Summer mode (only active when the external storage tank is con-
nected): turning the selector to the summer mode symbol
vates the traditional domestic hot water only function, the boiler supplies
water at the temperature set on the external storage tank.
If there is a domestic hot water request, the boiler switches on and the
boiler status indicator LED lights up with a fixed green light. The digital
20
MAXIMUM STRAIGHT LENGTH Ø 80
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
0
5
10
15
20
25
30
35
40
Suction pipe length (m)
(fig. 28) acti-
45
50
55
60
65
70
75
80
85
90
display shows the hot water system temperature, the icon to indicate the
hot water supply and the flame icon (fig. 30).
Adjustment of the domestic hot water temperature
CASE A heating only with storage tank - adjustment does not apply
CASE B heating only + external storage tank with thermostat - adjustment
does not apply.
CASE C heating only + external storage tank with probe - to adjust the
temperature of the domestic hot water in the storage tank, turn the knob-
but with the symbol
and anti-clockwise to lower it.
On the control panel, the green LED flashes with ON for 0.5 seconds, OFF
for 3.5 seconds.
The boiler is standby status until, after a heat request, the burner switches
on and the indicator LED turns fixed green to indicate flame presence.
The boiler continues to operate until the temperatures set on the boiler are
reached, or the heat request is met; after which it goes back on standby.
If the red LED indicator near the
lights up, this means the boiler is in temporary shutdown status (see the
chapter on Light signals and faults).
The digital monitor indicates the fault code detected.
Automatic Temperature Control System function (S.A.R.A.) fig. 34
Setting the heating water temperature selector to the area marked "AUTO"
(temperature range 55 to 65°C), activates the automatic temperature con-
trol system (frequency 0.1 sec. on; then 0.1 sec. off; for 0.5 seconds):
according to the temperature set on the room thermostat and the time
taken to reach it, the boiler varies automatically the heating water tem-
perature reducing the operating time, allowing greater ease of operation
and energy saving. On the control panel, the green LED flashes ON for
0.5 seconds, OFF for 3.5 seconds.
Reset function
To restore operation, set the function selector to
onds then set the function selector to the required position, checking that
the red indicator light is OFF.
At this point the boiler will automatically start and the red lamp switches
on in green.
N.B. If the attempt to reset the appliance does not activate operation,
contact the Technical Assistance Service.
4.2 Switching off
Temporary switch-off
In case of absence for short periods of time, set the mode selector (fig.
31) to
(OFF).
In this way (leaving the electricity and fuel supplies enabled), the boiler is
protected by the following systems:
Anti-frost device: when the temperature of the water in the boiler falls
below 5°C, the circulator and, if necessary, the burner are activated at
minimum output levels to bring the water temperature back to the values
for safety (35°C). During the anti-frost cycle, the symbol
pears on the digital monitor.
95
100
105
110
(fig. 32) clockwise to increase water temperature
symbol (fig. 33) on the control panel
(fig. 31), wait 5-6 sec-
(fig. 35) ap-