4.11

Status values

The status values can be checked via the remote control by following these steps
M
Step 1: Keep pressing
M
M
Step 2: Press
et
M
Step 3: Press
to return to the main screen.
Status values table
Description
01
Water inlet temperature
02
Water outlet temperature
03
Ambient temperature
04
Air outlet temperature
05
Air inlet temperatur
06
Outside coil temperature
07
Inside coil temperature
08
The openness of the expansion valve
09
Reserved
10
Compressor current (A)
11
PCB temperature (°C)
12
Fan motor current (A)
13
Compressor real frequency (Hz)
14
Main PCB current (A)
15
Fan motor speed (RPS)
4. Use
until you enter the settings verification mode.
to check the status values.
26
Valeurs
-30~99°C
-30~99°C
-30~99°C
0~125°C
-30~99°C
-30~99°C
-30~99°C
0~2500, Real=display
value*2