use of any other hose and regulator assembly could be
dangerous, and may not provide adequate gas supply to
the summit
built-in gas grill, and could result in a fire or an
®
explosion causing serious bodily injury or death and damage
to property.
Failure to build an LP cylinder enclosure for a 20 lb cylinder
following the requirements for ventilation, cylinder retention
and separation of the lp cylinder from a heat source, listed
in the ansi standard for outdoor Cooking Gas appliances,
ANSI Z21.58 CSA 1.6, could be dangerous, and could result
in a fire or an explosion causing serious bodily injury or
death and damage to property.
if you do not follow the danGer statements exactly, the warranty on the summit
built-in gas grill will be voided.
◆
loCatinG Your lp tanK enClosure Kit
When determining a suitable location for your LP Tank Enclosure Kit installation, give
attention to concerns such as proximity to traffic paths, and keeping any gas supply
lines as short as possible. Never locate the Summit
breezeway, shed, under an unprotected overhang, or other enclosed area. Locate the LP
Tank Enclosure Kit and structure so there is enough room to safely evacuate the area in
case of a fire.
◆
ClearanCe from Combustible surfaCes or
struCtures
m warninG: Clearance from the outside walls of the sides
and back of the lp tank enclosure must be a minimum of
24" (60.96 cm) any surface. Refer to "Typical Gas Supply
installation" before starting installation.
m warninG: the structure, "island" counter tops and
adjacent work areas for the lp tank enclosure must be built
from noncombustible materials only.
NOTE: If you have questions on what materials are considered noncombustible, contact
you local building supplier or fire department.
bUILT-IN TaNK ENcLoSUrE INSTrUcTIoNS
m danGer
m danGer
LP Tank Enclosure Kit in a garage,
®
◆
ENcLoSUrE SPEcIFIcaTIoNS
b
1
®
1
a
b
c
c
1
1
a
24" (610 mm) any surface
LP tank enclosure
Any surface
Non-combustible surface
WWW.WEbEr.com
b
®
27